SPECIFICATIONS
External fire dimensions (mm)
Performance
Model
Model No.
Width
Depth
Height
Average
emissions
Average
efficiency
ECAN NO *
Cardrona
KWF295-6960
535
490
648
0.80g/kg
69%
165498
Oxford
KWF295-6961
535
490
648
0.80g/kg
69%
165500
Benmore
KWF295-6962
535
490
648
0.80g/kg
69%
165499
Haast
KWF295-6950
575
560
730
0.98g/kg
66%
144660
Murchison
KWF295-6952
575
560
730
0.98g/kg
66%
144662
Aspiring
KWF295-6951
575
560
730
0.98g/kg
66%
144661
Ruapehu
KWF295-6965
760
588
718
0.54g/kg
66%
191312
* ECAN NO = Environment Canterbury authorisation number.
TABLE 1
N
N
Minimum Installation Clearances (with flue shield) mm
Hearth Clearances (mm)
Model
Model No.
A
B
C*
D
E
F
G
H
J
K
L
M
N
Cardrona
KWF295-6960
135
350
300
130
120
270
610
395
795
855 1140
585 1000
Oxford
KWF295-6961
135
350
300
130
120
270
610
395
795
855 1140
585 1000
Benmore
KWF295-6962
135
350
300
130
120
270
610
395
795
855 1140
585 1000
Haast
KWF295-6950
160
360
300
130
190
320
645
500
835
960 1340
640 1160
Murchison
KWF295-6952
160
360
300
130
190
320
645
500
835
960 1340
640 1160
Aspiring
KWF295-6951
160
360
300
130
190
320
645
500
835
960 1340
640 1160
Ruapehu
KWF295-6965
150
200
300
100
170
315
580
540
960
913
1375
640 1180
*
Fuel loading opening to end of floor protector.
Wall Clearances
Corner Clearances
FIG. 1
TABLE 2
MINIMUM INSTALLATION CLEARANCES
Description
Model No.
Standard - 4.2m
KWF298-7005
Tested to AS/NZS 2918, Appendix F, ARS report No;02/649
Energy Saver - 4.2m
KWF298-7006
Tested to AS/NZS 2918, Appendix F, ARS report No;02/649
Sloping Ceiling - 4.2m
KWF298-7354
Tested to AS/NZS 2918, Appendix F, ARS report No;14/2718
RECOMMENDED FLUE KITS FOR KENT FREE STANDING WOOD FIRES