background image

Instructions For Use - Charger:

The LED Light on the Charger

Power On (Green light flashes slowly)

Battery Low (Red light stays illuminated)

Battery Charged 80% (Green light flashes rapidly)   

Battery Charged 100% (Green light stays illuminated)

Battery Pack temperature is too hot or too cold (Red light flashes slowly)

Battery Pack malfunction (Red and Green lights stay illuminated)

WARNING

1. Charger is plugged into a 100 – 240 V a.c outlet only.

2. If the battery pack is too hot or too cold, the charger will not fast charge the battery pack and 
the red indicator light is “blinking”. When the battery pack temperature returns to between 0° C 
(32° F) and 50° C (122° F), the charger will automatically begin charging.

3. If both red and green indicator lights are “ON” the battery pack either does not comply or is 
defective. Please contact your local KENT office.

4. Do  not  charge  the  battery  pack  in  the  rain,  snow  or  high  temperature environment.

5. Do not charge battery pack when environment temperature is below 0° C (32° F) or above 
40° C (104° F).

6. While charge the cool battery pack (below 0° C) in the warm indoor, keep the battery pack in 
the room for one hour to warm up before starting the battery pack. A cool battery may charge 
unsaturated.

7. Remove the plug after finishing the charge.

8. Do not use generator for charging the battery pack.

Summary of Contents for 86350

Page 1: ...Caulking Gun Charger and Battery Pack with enough space for additional spare Battery Pack not included P N Product S C 86350 Battery Caulking Gun 10 8V 400 ml BCG400 86366 Battery Caulking Gun 10 8V 600 ml BCG600 86351 Battery Pack for BCG 86350 86366 86352 Charger for Battery Pack 86351 86531 KIT Spare Plunger for BCG incl plunger disc screw plastic plunger disc pushing block 86434 UK plug for Ch...

Page 2: ...ed Kingdom TA6 6AJ All rights reserved Terms and Conditions No part of this publication may be reproduced transmitted or stored electronically mechanically or photocopied without the prior permission of KENT United Kingdome Ltd This data sheet and its contents the Information belong to the KENT United Kingdome Ltd or are licensed to it No licence is granted for the use of it other than for informa...

Page 3: ...and try to charge it once more 3 When you charge a new battery pack or a battery pack which has not been used for a long period it may not accept a full charge This is a normal condition and does not indicate a problem You can recharge the battery pack fully after discharging it completely a couple of times 4 If you wish to charge two battery packs allow 15 minutes between charging on the fast cha...

Page 4: ...ht is blinking When the battery pack temperature returns to between 0 C 32 F and 50 C 122 F the charger will automatically begin charging 3 If both red and green indicator lights are ON the battery pack either does not comply or is defective Please contact your local KENT office 4 Do not charge the battery pack in the rain snow or high temperature environment 5 Do not charge battery pack when envi...

Page 5: ...back into the plunger disk and tighten it Fig 7 4 Screw back on the compound holder then remove the front cap 5 Use a sharp knife to cut the tip of caulking tube at least 3 mm in diameter This will allow the tool to provide an optimal seam width for most of applications Fig 8 6 Use the sharp tip to jab the aluminum vela men on the caulking tube Fig 9 7 If you use a open tube left from last time or...