INTRODUCTION

This  manual  will  help  you  get  the  most  from  your 

SelecTrac™

.    Read  it

thoroughly before operating the machine.

This product is intended for commercial use only.

PARTS AND SERVICE

Repairs,  when  required,  should  be  performed  by  your  Authorized  Nilfisk-
Advance Service Center, who employs factory trained service personnel, and
maintains an inventory of Nilfisk-Advance original replacement parts and acces-
sories.

Call the NILFISK-ADVANCE DEALER named below for repair parts or service.
Please specify the Model and Serial Number when discussing your machine.

NAME PLATE

The  Model  Number  and  Serial  Number  of  your  machine  are  shown  on  the
Nameplate on the machine.  This information is needed when ordering repair
parts for the machine.  Use the space below to note the Model Number and Serial
Number of your machine for future reference.

MODEL NUMBER

SERIAL NUMBER

UNCRATE THE MACHINE

When the machine is delivered, carefully inspect the shipping carton and the
machine for damage.  If damage is evident, save the shipping carton so that it
can be inspected.  Contact the Nilfisk-Advance Customer Service Department
immediately to file a freight damage claim.

PREPARATION

VACUUM / SOLUTION HOSE ASSEMBLY (FIG. 3,4)

This machine uses a vacuum / solution hose assembly with a wand attachment.
To assemble, connect one end of the vacuum hose to the tank lid by pushing it
on. The solution line male fitting connects to the coupling at the rear of the
machine on the base. Slide the knurled collar on the female fitting back. Push the
hose’s male fitting in, and release the knurled collar until it snaps back.The other
end of the vacuum / solution hose assembly attaches to the wand assembly in
the same way.

NOTE:  *IMPORTANT* FOR MODEL KX-17THP

Only use wand attachments and accessories that are rated for 200 PSI or more.
Failure to do so could result in damage to machine, attachment, accessory, or
surface being cleaned. Included with your machine is a high pressure nozzle.
Use this nozzle with attachments to provide correct solution flow, pressure, and
avoid overwetting carpet.

ADDING SOLUTION  (FIGURE 5)

WARNING!

DISCONNECT THE POWER CORD FROM THE ELECTRICAL
OUTLET BEFORE ADDING SOLUTION.

Be sure the drain valve is closed. Lift lid into the upright position and pour clean
solution into the front of the tank as directed by the “Solution” arrow to the fill line.
DO NOT pour clean solution into the recovery bladder.

CAUTION!

Solution temperature must not exceed 170°F (76°C). Use non-
foaming chemicals or defoamer and be sure to use the correct
dilution ratios.

PUMP PRIMING  (FIGURE 6)

KX-17THP Model only - Prime the pump system by connecting the drain hose,
which is the 4 foot long solution hose with a connection on one end, to the quick-
disconnect at the back of the machine and place the open end of the hose in the
solution tank.  Turn on the pump, thereby recirculating the clean water through
the drain hose back into the solution tank.  When there is a steady stream of
water  running  through  the  drain  hose  the  pump  is  primed  (usually  2-3
minutes).Turn off the pump and disconnect the priming hose and attach the
solution hose.

NOTE:

 The pump rarely needs to be primed after the first time.  If the solution

tank is allowed to run low, which results in the pump drawing air, then the pump
may need to be primed again.  Erratic pressure fluctions indicates air in the lines
and means that the pump needs priming.

CONTROLS

VACUUM SWITCH  (FIGURE 7)

Turns the vacuum motor on to pick up solution with the recovery nozzle and
collects it in the recovery bladder.
 ‘O’ is “OFF” and ‘I’ is “ON”.

PUMP SWITCH  (FIGURE 7)

Turn the pump on to pump solution from the tank, through the spray nozzle to
the floor.
‘O’ is “OFF” and ‘I’ is “ON”.

OPERATION

Before  each  use,  check  the  solution  tank  filter  (Figure  8),  vacuum  lint  filter
(Figure 9), recovery nozzle, and spray nozzle for lodged debris. After filling the
tank with solution, plug the power cord into a grounded outlet. Turn on the
vacuum and solution switches.

CAUTION!

Do not allow water or foam to overflow and enter the vacuum tube
on the recovery bladder. If this happens immediately shut off the
vacuum motor, unplug the machine and contact an authorized
service center.

CLEANING CARPET

Slowly pull the tool towards you with the solution valve trigger engaged, then
make a pass forward and backward with the vacuum only (no spray) over the
cleaned area to remove as much dirt and solution as possible. Make overlapping
passes to prevent streaking.

CAUTION!

If foam appears on vacuum lid, turn the VACUUM SWITCH OFF
IMMEDIATELY.  Add more defoamer to the recovery bladder.

NOTE: DO NOT OVERWET CARPET!

If the carpet is heavily soiled, squeeze solution valve lever on the forward pass
and  backward pass, allowing cleaning solution a few seconds longer to work
prior to vacuuming.  Another method is to raise the wand 8" above the carpet and
pre-spray lightly prior to cleaning passes.  On extremely soiled carpets, it is
recommended the use of a pre-spray solution.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 56648033

Page 1: ...7 00 Form Number 56041494 083471M 1 OPERATOR MANUAL Kent MODELS 56648033 56648035 SelecTrac 17T 17THP h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 2: ...1494 SelecTrac 17T 17THP FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 3: ... shock do not handle the plug or machine with wet hands To unplug the cord grasp the plug Do not pull on the cord Donotuseextensioncordsoroutletswithinadequatecurrentcarryingcapacity Donotusewithadamagedcordorplug Connect the machine only to a properly grounded outlet refer to GROUNDING INSTRUCTIONS Avoid damaging cord closing doors on cord pulling around sharp edges or corners hot surfaces or run...

Page 4: ... del cordón No use cordones de alargamiento o tomacorrientes con una capacidad de corriente inadecuada No la use con un cordón o un enchufe dañado Conecte la máquina solamente a un tomacorrientes bien conectado a tierra consulte las INSTRUCCIONES DE PUESTA A TIERRA Trate de no dañar el cordón cerrando puertas y dejando el cordón aprisionado tirando contra bordes puntiagudos o esquinas superficies ...

Page 5: ... m long PLEASE NOTE FOR NORTH AMERICA ONLY 120VAC INTRUCCIONES PARA HACER LA TOMA A TIERRA Este aparato deberá ser conectado a tierra En caso de malfuncionamiento o de desperfectos la toma a tierra proporciona una vía de menor resistencia de la corriente eléctrica para reducir el riesgo de choques eléctricos Esta unidad viene equipada con un cordón con conductores para toma a tierra y con un enchu...

Page 6: ...ladder CAUTION Solution temperature must not exceed 170 F 76 C Use non foaming chemicals or defoamer and be sure to use the correct dilution ratios PUMP PRIMING FIGURE 6 KX 17THP Model only Prime the pump system by connecting the drain hose whichisthe4footlongsolutionhosewithaconnectionononeend tothequick disconnect at the back of the machine and place the open end of the hose in the solution tank...

Page 7: ... Attach the drain elbow on the drain valve Place a pail under the down spout and pull up the drain valve T handle Dirty solution will pour out until the bladder is empty Close the drain valve Use a clean bucket when you refill the solution tank EMPTYING THE SOLUTION TANK FIGURE 12 For model KX 17T place a bucket under the drain valve Remove the recovery bladder fork slide the bladder off the seal ...

Page 8: ...spray spray is weak or uneven from nozzle Clogged nozzle coupler or solution filter screen Debris inside pump or plumbing Punctuered pump diaphram 100 PSI pump only Defective or clogged pump check valve 100 PSI pump only Worn pump bearing this makes excessive noise Cracked pump housing Defective rectifier or motor Lost pump prime 300 PSI pump Pressure regulator set incorrectly 300 PSI pump only Va...

Page 9: ...ymouth MN 55447 3408 www nilfisk advance com Phone 800 989 2235 Fax 800 989 6566 2000 Nilfisk Advance Inc Plymouth MN 55447 3408 Printed in the U S A h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Reviews: