PhysioSuite
®
Modular System
Fully integrated touch screen control and display
User’s Guide
Page 1: ...PhysioSuite Modular System Fully integrated touch screen control and display User s Guide...
Page 2: ...oration Documentation Version 2 0 for On Unit Help Version 5 03 and Firmware Revision 2 00 00 60 August 2019 PhysioSuite Modular System Fully integrated touch screen control and display User s Guide T...
Page 3: ...Automatic Ventilator Set Up Hardware 6 Initial Set Up 7 Configure Settings 8 Procedure for Use 10 Constant Flow Mode 11 Raw Override Mode 11 Troubleshooting 12 MouseSTAT Pulse Oximeter and Heart Rate...
Page 4: ...RightTemp Temperature Monitor and Homeothermic Warming Set Up Hardware 21 Initial Set Up 22 Procedure For Use 23 Troubleshooting 23 RightTemp Pad and Sensor Maintenance 24 Data Management Connecting t...
Page 5: ...or authorized for use in human applications System Components Front Panel Back Panel Note If your PhysioSuite was purchased with RoVent it will contain four airflow ports If it was not purchased with...
Page 6: ...creen to view the parameters and important settings for each module Touch the tab again to open the module s extended Setup Menu Touch Screen PhysioSuite Menu offers quick access to most features and...
Page 7: ...to a location Press Dial A when finished ii Charts Charts allow you to customize the graph that is displayed on the lower portion of the Custom Run Screen You can customize two independent charts Cho...
Page 8: ...ll text on the run screen displays the assigned Parameter name for each Dial if set and its current value Run Screen with Dial Function Text As you turn a Dial setting changes takes place immediately...
Page 9: ...or sound Type Choose status to trigger alarm Value Set the threshold value Delay Choose how long the value must meet the threshold before triggering the alarm Clear Choose how the alarm needs to be c...
Page 10: ...ports of the PhysioSuite Note The PhysioSuite RoVent is designed to operate with the ports at neutral pressure The Bypass Assembly is required to neutralize any pressure buildup in the rear tubing Ba...
Page 11: ...calibration will measure the volume of tubing between the PhysioSuite RoVent module and the animal It is important that the Deadspace is recalibrated every time the tubing configuration is changed to...
Page 12: ...ess Dial B When asked to confirm measurement press Dial B again Configure Settings Configure all ventilator settings from the Vent Run Screen Pressure Priority RoVent ventilates to a specified inspira...
Page 13: ...Choose the time between the end of active inspiration and the start of expiration o Useful to increase oxygenation in certain respiratory models Assist Mode Change the breath pattern o Choose how an...
Page 14: ...hese settings turn Dial A or Dial B Touch Setup from the Vent Run Screen to make other changes to Respiratory Rate Target Pressure Tidal Volume or other advanced settings 4 From the Vent Run Screen to...
Page 15: ...ow can be adjusted and controlled as needed Note Air Mode is not a mechanical ventilation feature and will not control the animal s respiration Raw Override Mode For setups where the RoVent s safety p...
Page 16: ...n matter in the tubing or in the exhaust valve The exhaust outlet is blocked The endotracheal tube is not seated correctly Deadspace calibration is incorrect for current tubing setup Solution The high...
Page 17: ...cuits Resulting Message Meaning Possible Action Test OK Tubing leaks No leaks found None is needed The tubing is open to the atmosphere through a loose connection or a crack or hole in the tubing Tigh...
Page 18: ...o the MouseSTAT port on the back of the PhysioSuite 2 Connect the sensor to the interface cable and ensure that the connection is secure C F C F The MouseSTAT Run Screen The MouseSTAT Run Screen Initi...
Page 19: ...lenging Always warm the animal to support circulation in the animal s extremities 2 Align the sensor over the hind paw of the animal centering the red light over the paw pad MouseSTAT sensor on animal...
Page 20: ...ement Reposition sensor on the animal s paw Poor animal circulation Investigate types and dosages of anesthetic and other drugs in use reduce where possible Increase animal body temperature to encoura...
Page 21: ...connection is secure 2 Insert 1 the sampling assembly into the back slot of the side stream unit 2 the sampling needle into the expiratory line of the ventilator as close to the animal as possible 3...
Page 22: ...18 PhysioSuite Ventilator and CapnoScan Setup PhysioSuite CapnoScan with External Ventilator Setup...
Page 23: ...r your animal This can be adjusted from the CO2 Run Screen by pressing and turning Dial B Gas temp Choose the temperature of the expiratory gas When measuring an animal s ETCO2 use the default value o...
Page 24: ...g tube dirty or damaged Ensure that the sampling tube is not wet soiled or damaged Remove the sampling assembly from the CapnoScan sensor and clean the window gently CapnoScan not running or not conne...
Page 25: ...Pad Sensor port Setup Diagram C F C F 5 Secure the pad temperature sensor in the center of the warming pad using tape etc If using the included disposable pad covers make sure the sensor is positione...
Page 26: ...se the and icons to set a warming level 2 The pad will automatically begin to warm a The Pad Temperature is displayed in the top half of the screen Note If the sensor should fail during use the RightT...
Page 27: ...nabled for warming and target temperatures are selected Incorrect or loose connections Ensure that the connection at the back of the PhysioSuite is tight Pad is overheating Incorrect sensor placement...
Page 28: ...nsor Maintenance Use the disposable warming pad covers to prevent soiling the warming pad Wipe the warming pad clean with a damp cloth if needed Never saturate the warming pad Gently wipe the sensors...
Page 29: ...you connect your device to a PC via miniUSB cable If the driver does not install automatically you can install it manually from http www ftdichip com Drivers VCP htm COM Port Settings Bits per second...
Page 30: ...mat up to 1000 rows You can send this data to a PC through the USB port at a later time Each row can include up to 10 Parameters simultaneously at user selected time intervals You can view the data on...
Page 31: ...s have been adjusted and the program you plan to use is running Refer to the Data Management Guide for more information 2 From any Run Screen Touch 1 Menu then Data Management then History 3 Choose 1...
Page 32: ...nu then Data Management then Analog Output 3 Choose a Parameter to output The voltage output ranges from 0 3V with 0V assigned to the low limit of the range and 3V to the high limit See Custom Run Scr...
Page 33: ...n s financial obligation extend beyond the cost of or replacement of the Kent product in question Kent Scientific Corporation also reserves the right to make any improvements or modifications to these...
Page 34: ...hout a RMA number will not be accepted Please note that after our 30 day return policy period ends we will be happy to assist you with your application but cannot issue any credit or refund for a retu...
Page 35: ...12 0mL Weight Range 3g to 1 250g Heart Rate Up to 900bpm Resolution SpO2 Range 1 70 to 100 Alarms 5 programmable Data Export Yes SpO2 Sensors Mouse Soft Touch paw sensor Rat Soft Touch paw sensor or l...
Page 36: ...fications within 2 minutes CO2 measurement range 0mmHg to 120mmHg 0 to 16 0kPa to 20kPa at 760mmHg Barometric Pressure supplied by host Rise time Less than 60ms CO2 resolution 0 1mmHg at 0mmHg to 69mm...
Page 37: ...8 18 dial menu 3 driver 24 enable 22 25 enabled while running 25 endotracheal tube 6 7 11 exhaust 6 11 exhaust port 6 external vent 17 fixed alarms 5 flow control 24 gas temp 18 hardware 6 13 16 20 h...
Page 38: ...l 26 send new 26 sensor 1 13 16 18 23 30 31 set ranges 3 set target pressure 8 set target volume 8 settings 2 3 5 7 10 18 19 22 24 26 side stream 16 sigh breath 9 30 specifications 29 31 target pressu...
Page 39: ...1116 Litchfield Street Torrington Connecticut 06790 Local 860 626 1172 Toll Free 888 572 8887...