51026WDGCOPSOL ASSEMBLY INSTRUCTIONS
If the pump fails to run:
With low flow rate, the pump will spew or “burp”:
• Make sure the solar panel is receiving direct sunlight. Performance
is directly related to the amount and strength of sunlight received.
• See solar panel troubleshooting. You may need to boost charge
or replace the battery.
• Check tubing for kinks and obstructions.
• Check connections between pump and panel and battery.
• Clean pump as described below.
• Check the water level to make sure the pump is completely
submerged, water should always be above the min fill line (not
all water features include min fill line).
If abnormal noise is heard during operation (with water):
• Disconnect the power supply and then remove the pump front
cover and impeller cover.
• Use hand to grip the impeller, gently pull the impeller/rotor
assembly out of the pump housing.
• Rinse the impeller/rotor assembly and the cavity with clean water.
You may also use a soft brush to clean pump surfaces.
If breakage or surface damage is found in the assembly contact
Customer Support for a part replacement.
PUMP SAFETY & TROUBLESHOOTING
To keep water clean
• Periodically change water to prevent algae buildup.
Filter sponge
Filter/ Front cover
Impeller cover
Rotor/Impeller
Pump housing