IN USE

When in use the power indicator turns green. The 4 progressive performance 
bars will appear. A normally functioning unit should have all 4 performance 
bars lit. If there are consistently less than 2 bars, you should check for the 
problem. Possible issues causing the performance bars to lessen could be:

1. Blocked suction at the hose end

2. Clogged pipe in system

3. Air restrictive tool being used, such as a crevice tool

4. Full dirt receptacle

5. Clogged filtration system

EMPTY DIRT RECEPTACLE

Every 25 hours of use (approximately 6 months) the empty dirt receptacle 
indicator will flash on the screen. This is an indication to check the dirt 
receptacle and empty it. Since this is time based, you may find the dirt 
receptacle too empty or too full. If you have pets, a workshop or other 
factors that cause waste more frequently, you may wish to check the 
dirt receptacle more frequently.

Once the dirt receptacle is emptied, you push the return button to reset 
the 25 hours timer. If your power supply is interrupted, or otherwise 
unplugged, the empty dirt receptacle indicator will keep a memory of its 
previous status and continue life measure.

To manually reset the Empty Dirt Receptacle indicator, simply press the 
button lining up with the Enter symbol, and hold for 10 seconds.

LIFE METER

The life meter has 8 bars on it. Once these bars are depleted you unit will 
continue to run, although it is strongly recommended to take it to your local 
service center to be inspected and serviced. A life bar will deplete every  
65 hours of vacuum use, meaning your central vacuum will have a long life 
of service to you. The life meter can be reset only by your service technician. 
If you power supply is interrupted, or otherwise unplugged, the life meter 
will keep a memory of its previous status and continue life measure.

SERVICE INDICATOR

If there is a system fault, or malfunction with your power unit, the service indicator 
will flash. Upon seeing this symbol, we recommend that you turn the power 
unit off, unplug the power supply for 10 seconds and then plug it back in. If the 
service symbol is still on the screen, we recommend that you call for service.

This symbol may appear due to the following faults:

•  Motor problem

•  Electronic problem

•  Voltage or current problem (too high or too low)

•  Power unit not responding to electronics

SCROLLING YOUR LCD

When not in use, you can scroll through the features of your LCD to 
observe the dirt receptacle status, life monitor measure or most recent 
recorded power level.

To scroll through these features simply push the button corresponding 
with the right pointing arrow symbol. 

The next screen you will see will be the Life Meter. Scroll right further 
and you will find Bucket Status. Yet another scroll will show you last 
recorded performance levels of the power unit, using the Performance 
Meter on the In-Use screen. The final scroll right will show you the customer 
service phone number.

The button lining up with the left scroll button will allow you to scroll 
backwards through the screens. 

BAG ADAPTOR

Your power unit can all be fitted with a convenient paper bag for more 
convenient dirt disposal. For maintenance of the paper bag, please see 
the Paper Bag Filter section, under Filter Maintenance.

Refer to page 15 - Image 10

UTILITY VALVE

The utility valve is similar to an Inlet valve, but is located near the power 
unit. This valve is present for your convenience, as it can help clean up 
any dirt spilled close to the central vacuum. 

OVERHEATING PROTECTION

If the circuit board reaches an elevated temperature, the power unit the 
power unit will not operate and the LED will be off or on LCD model the 
screen will be flashing. In the event of these problems, press the On/Off 
button, unplug hose or wait for temperature to lower. If problems persist; 
contact your authorized dealer or distributor.

Refer to page 15 - Image 9

OVERLOAD PROTECTION

The central vacuum system employs features that monitor the following operating 
levels: AC voltage, and current draw. If the voltage is below or above standard  
operating voltage, high current draw or locked rotor, the power unit will not 
operate. In this case the On/Off button will blink until the problem ceases or on 
the LCD model the screen will flash. If problems persist; contact your authorized 
dealer or distributor. The power unit requires 30 minutes to cool down.

Refer to page 15 - Image 9

DIAGNOSTICS AND MAINTENANCE

Reduced airflow or suction indicates the central vacuum system is not 
operating at maximum efficiency. If the dirt receptacle is full and the filter 
is clogged, no air can pass through the unit and no cleaning can take place. 
Instructions provided in the booklet serve as a guide to routine maintenance. 
Proper airflow or suction can be maintained by keeping the dirt receptacle 
and filter clean and the plastic tubing and hose free from clogs.

EMPTYING THE DIRT RECEPTACLE

Most models feature dirt receptacles with windows to tell at a glance when 
the dirt receptacle should be emptied. In most cases, the dirt receptacle 
only needs to be emptied two to three (2-3) times a year. To remove the dirt 

Summary of Contents for TYPE K

Page 1: ...Central Vacuum Systems Owner s Manual Type K Système central d aspiration Manualdupropriétaire Type K 460445 ...

Page 2: ...king as it should has been dropped damaged left outdoors or dropped in water return it to a service center Connect to a properly grounded outlet only refer to grounding instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or cord ...

Page 3: ...ood For prompt and complete service information always refer to these numbers when inquiring about service WARNING Non observance of the safety directions may result in bodily harm PRODUCT DIMENSIONS Refer to page 15 Image 1 WASTE OF ELECTRIC AND ELECTRICAL EQUIPMENT WEEE This symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it sho...

Page 4: ...o allow suction to decrease thus protecting the inlet valve seal Refer to page 15 Image 8 LED Indications Optional Depending on model You machine may be equipped with some or all of the indicators listed below Refer to page 15 Image 9 On Off Motor Fault Dirt Receptacle Full Reset Your power unit is equipped with a multi color LED panel This LED panel will provide you with necessary information on ...

Page 5: ...life monitor measure or most recent recorded power level To scroll through these features simply push the button corresponding with the right pointing arrow symbol The next screen you will see will be the Life Meter Scroll right further and you will find Bucket Status Yet another scroll will show you last recorded performance levels of the power unit using the Performance Meter on the In Use scree...

Page 6: ... the hose obstruction insert a blunt instrument into the hose garden hose wood dowel You can also attempt to reverse the suction through the hose to dislodge the blockage Refer to page 15 Image 12 and 13 If there is one inlet valve without normal suction and you have checked for hose blockage then the blockage is in the pipe system between the blocked inlet valve and the power unit see instruction...

Page 7: ... tools fail to perform due to manufacturing defects return it to your nearest Sears service depot and they will repair or replace free of charge Limitations and Exclusions This warranty does not apply to products purchased outside Canada or to any product which has been improperly installed and or assembled subjected to usage for which the product has was not designed misused or abused damaged dur...

Page 8: ...centre de service Branchez le dans un prise de courant correctement mise à la terre seulement consultez la section Instructions pour mise à la terre N utilisez pas de cordons de rallonge ou de prise dont l intensité de courant admissible n est pas acceptable Fermez toutes les commandes avant de débrancher Ne débranchez pas en tirant sur le cordon Pour débrancher tirez la fiche pas le cordon Ne man...

Page 9: ...es instructions contenues dans ce manuel servent de guide pour l entretien de routine Pour plus d information communiquez avec votre détaillant ou distributeur autorisé local PLAQUE SIGNALÉTIQUE Le type et les numéros de modèle et de série sont indiqués sur la plaque signalétique qui se trouve sur le panneau de commandes ou sur le capot du moteur Pour obtenir rapidement des informations complètes ...

Page 10: ...aire Pour un contrôle ultime de la qualité de l air optez pour la série 650 La série 650 est dotée d un filtre HEPA authentique et peut être intégrée à l unité motrice que vous choisissez ou peut être achetée chez un détaillant ou un distributeur autorisé Vous n avez qu à fixer le filtre HEPA authentique tel que montré Voir à la page 15 Image 7 VÉRIFICATION DU SYSTÈME Assurez vous que votre instal...

Page 11: ...gression de la performance apparaîtront Lorsqu une unité motrice fonctionne normalement les 4 barres de performance devraient être allumées S il y a constamment moins de 2 barres vous devriez vérifier quel est le problème 1 Blocage de la succion à l extrémité du boyau 2 Obstruction dans la tuyauterie du système 3 Utilisation d un accessoire à débit d air restreint par exemple un outil de coin 4 Cu...

Page 12: ...our les modèles à ACL l écran clignotera jusqu à ce que le problème cesse Si le problème persiste communiquez avec votre détaillant ou distributeur autorisé L unité motrice a besoin d un temps de refroidissement de 30 minutes avant d être redémarrée Voir à la page 15 Image 9 DIAGNOSTICS ET MAINTENANCE Une réduction du débit d air ou de la succion indique que le système central d aspiration ne fonc...

Page 13: ...a un fusible sauté ou un disjoncteur déclenché dans la boîte d alimentation principale de la maison Débranchez l unité motrice et vérifiez tous les branchements des prises d admission et toutes les connexions à basse tension pour vous assurer que tous les fils sont bien fixés Si l unité motrice ne démarre toujours pas communiquez avec le détaillant ou le centre de service autorisé le plus près UNI...

Page 14: ...blement à cause de défauts de fabrication rapportez le à votre centre de service Sears le plus près et ils le répareront ou le remplaceront sans frais LIMITATIONS ET EXCLUSIONS Cette garantie ne s applique pas aux produits achetés à l extérieur du Canada ni à un produit qui a été incorrectement installé et ou assemblé soumis à un usage pour lequel le produit n a pas été conçu ou à un usage abusif ...

Page 15: ...n 70 cm 27 5 Maximum 1 8 m 6 from outlet de la prise de courant Min 30 cm 12 Min 30 cm 12 Min 30 cm 12 LCD Screen Écran ACL LED Buttons On Off Empty Dirt Receptacle Marche arrêt Cuve à poussière pleine Motor Status Reset État du moteur Réenclenchement 103 2 cm 40 5 49 5 cm 19 5 ...

Page 16: ...ine Pour la réparation des appareils électroménagers de grandes marques à votre domicile peu importe le fabricant ou le détaillant Pour connaître l emplacement du Service des pièces et de l entretien Sears le plus proche afin d apporter à l atelier des produits tels que des aspirateurs tondeuses à gazon ou appareils électroniques Pour connaître le n de téléphone du Service des pièces et de l entre...

Reviews: