About Advanced Features & Operation
Page 23
EMERGENCY HEAT -
Available if you have a Heat Pump
installed. To initiate the Emergency Heat feature, press the
FAN button. While holding the FAN button press the UP
button. The Cool setpoint display will read ‘EH’ (emergency
heat).
OPERATION: During Emergency Heat operation the
thermostat will turn on the fan and the 2nd stage of heat when
there is a demand for heat. Also during Emergency Heat the
1st stage or cooling will be unavailable.
EXIT EMERGENCY HEAT: Follow the same steps as entering
Emergency Heat by pressing the FAN and UP buttons. During
Emergency Heat, only OFF and HEAT modes are available by
pressing the MODE button.
:
Am
I2 00
73
M
Press for
Emergency Heat
FAN
FACTORY DEFAULTS -
press
the MODE button. While holding the Mode button, press the
FAN button for 5 seconds; all icons will appear. Press and
hold the FAN button until
Fd
appears; this resets all factory
settings. To return to normal operation, press the MODE
button once.
If, for any reason, you desire to return all
the stored settings back to the factory default settings,
Eh
70
o
HEAT