1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT – RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts, or washers used to complete a path to ground
are removed for service, they must be returned to their
original positions, and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals,
possessing adequate backgrounds of electrical, electronic,
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Freezer Compartment)...-6°F to +8°F
Defrost Control...Total Comp Running Time : 7 hrs ~ 50 hrs
Defrost Thermostat .......................................................46°F
Electrical Rating : 115VAC, 60Hz.................................1-5 A
Maximum Current Leakage.......................................0.5 mA
Maximum Ground Path Resistance ....................0.14 Ohms
Energy Consumption .....21 cu.ft. 457 kWh/yr (Energy Star)
.......................................25 cu.ft. 476 kWh/yr (Energy Star)
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
Ambient of:..........................70°F..................................90°F
Fresh Food, °F ....................33°F to 41°F.........33°F to 41°F
Frozen Food, °F ..................-4°F to +4°F ..........-4°F to +4°F
Percent Running Time ........35%-45% .................50°F-70°F
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ............... 20 MIN.
Minimum Equalized Pressure
@ 70°F ....................................................... 52 PSIG
@ 90°F ....................................................... 59 PSIG
Refrigerant R134a ................................................. 4.59 oz.
Compressor ..................................................... 821 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides, and rear of the
refrigerator for air circulation.
AT TOP ......................................................................... 2 in
AT SIDES ...................................................................... 1 in
AT REAR ...................................................................... 1 in
1-7 REPLACEMENT PARTS
21 cuft
795. 78712.801 795. 78722.801
795. 78713.801 795. 78723.801
795. 78714.801 795. 78724.801
Relay
EBG44308701
Overload
EBG44308701
Defrost Thermostat
6615JB2005H
Defrost Heater
5300JK1005D
Evaporator Fan Motor
4681JK1004D
Capacitor (Running)
0CZZJB2014G
Compressor (Hi-Side)
2521JA1006L
Evaporator (Lo-Side)
5421JJ1003B
Condenser
ACG36653801
Dryer
5851JA2008U
Condenser Fan Motor
4681JB1029D
Temperature Control
EBR36499201
Main Control
6871JB1423M
1. SPECIFICATIONS
- 3 -
EVAPORATOR
COLD AIR
MIXED AIR
AIR RETURN TO
EVAPORATOR
FRESH FOOD
FREEZER
Ò
Vegetable box
EVAPORTOR FAN MOTOR
CONDENSER FAN MOTOR