- 19 -
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
5
1
4
3
YES
NO
YES
The range of resistance is between 1~50½ (ok)
Open or short
NO
Power source.
No voltage.
(Rated voltage
±10%)?
Replace OLP.
Reconnect.
Refer to page 12.
Refer to page 12.
Check connection
condition.
OLP disconnected?
Advise customer that
power supply needs to be
checked by an electrician.
Replace
compressor.
Supply
voltage rating
with ±10%.
Applied voltage isn't
in acceptable range.
(120V
AC
±10%)
Remove TSD-Starter
from compressor and
measure voltage
between terminal C of
compressor and
terminal 5 or 6 of TSD.
Check resistance
between M-C, S-C and
M-S in motor
compressor.
Check resistance of
two terminals in
TSD-Starter.
Check resistance of two
terminals in OLP.
Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).
Check
resistance of
motor
compressor.
Check
resistance of
TSD-Starter.
Check OLP.
Check
starting state.
Summary of Contents for Elite 795.78712.801
Page 19: ...5 CIRCUIT DIAGRAM 18 CIRCUIT DIAGRAMS ...
Page 54: ......