![Kenmore 796.88842800 Service Manual Download Page 10](http://html.mh-extra.com/html/kenmore/796-88842800/796-88842800_service-manual_183777010.webp)
4
COLUMBUS DRYER CYCLE PROCESS
9
Cycle
Sensor
Dry *
Manual
Dry **
Motor
Load
Heater
Default
Drying
Electro-
sensor
Temp-
control
Default
time
Temp-
Control**
Cooling
Wrinkle care
Time
Conditions of operation and termination
Temp-
erature
Dry
Level
Display
time
Heavy Duty
* Sensor dry : “Dry Level” is set by users.
** Manual dry : “Temperature control” is set by users.
Default settings can be adjusted by users.
High
Medium
High
Cotton/
Towel
Casual
Low
(Normal) 36min Saturation 55 5
(5min) (47 5
Low
(Normal) 32min Saturation 55 5
(5min) (38 5
(Normal) 55min Saturation 66 5
(5min) (47 5
Medium
Normal
(Normal) 41min Saturation 60 5
(5min) (47 5
(Midium
High)
Freshen Up
-
20min Saturation (66 5
(5min) (47 5
(High)
Speed Dry
-
25min Saturation (70 5
(5min) (47 5
-
Air Dry
-
30min Saturation
No
heater
N/A
N/A
(Normal) 54min Saturation 68 5
(5min)
3Hr
3Hr
Off Time: 6min
On Time: 10sec
Temperature Control for each cycle
(47 5
Sanitary
High
(Very) 1:10min Saturation 68 5
(5min) (47 5
Delicate