28
None
Turns on all LED
T1 and Main Program Version
1 time
Button Check
T2 and Display Program Version
2 time
None
T3
3 time
Inlet valve for Bleach Detergent turns on. (Cold Water)
A and Water level frequency (1~10 Level)
4 time
※
On :67~33(26.7kHz~23.3kHz)
※
The meaning of 67~33 number is 26.7kHz~23.3kHz really
Inlet valve for Softener Dispenser turns on. (Hot Water)
B and Water level frequency (1~10Level)
5 time
Inlet valve for J-Dispenser turns on. (Cold Water)
C and Water level frequency (1~10Level)
6 time
Heater check (on heater model)
T4 and the coefficient of flood sensing
7 time
Wave force check
T5 and the coefficient of load sensing
8 time
Drain pump check
T6 and Water level frequency
9 time
Pulsator operates for 3 minutes.
T7 and the coefficient of load sensing
10 time
High speed spin
T8 and RPM
Off
11 time
. Unlocks the door
None
. Turns off all LED
Number of times the
START/PAUSE
button is pressed
Check Pont
Display Status
1
1) SAFETY CAUTION
·
The main power board assembly has exposed live 120 VAC and live DC voltages. Use care when
disconnecting connectors during troubleshooting and testing. (Wear electrostatic discharge gloves when
handling the board.
·
Unplug the power when handling the board assembly. (Wear electrostatic discharge gloves when handling the
board. Store the board in an ESD [ElectroStatic Discharge] plastic bag.)
2) QC TEST MODE
·
The washer must be empty and the controls must be in the off state.
·
Press and hold the Water Temp. and SOIL LEVEL buttons; then press the POWER button. The buzzer will
sound twice.
·
Press the Start/Pause button to advance to the subsequent test mode step.
4-3. TEST RUNNING WITHOUT WATER