8
-2-7 Temperature Compensation & Overcooling/Undercooling Compensation Circuit
1. Refrigerator Temperature Compensation
2. The temperature compensation for refrigerator compartment is in the following table:
NOTE
: This circuit is designed to input the necessary temperature compensation values into the MICOM. This adjusts the
refrigerator temperature, which is different in each model.
- 35 -
Refrigerator
Resistance
Temperature Remark
(RCR)
Compensation
180 K
Ω
+2.5°C
Compensation by
56 K
Ω
+2.0°C
raising the
33 K
Ω
+1.5°C
temperature
18 K
Ω
+1.0°C
12 K
Ω
+0.5°C
10 K
Ω
0 °C
Standard Temperature
8.2 K
Ω
-0.5°C
Compensation by
5.6 K
Ω
-1.0°C
lowering the
3.3 K
Ω
-1.5°C
temperature
2 K
Ω
-2.0°C
470
Ω
-2.5°C
Revised resistance
470
Ω
2k
Ω
3.3k
Ω
5.6k
Ω
8.2k
Ω
10k
Ω
12k
Ω
18k
Ω
33k
Ω
56k
Ω
180k
Ω
Present resistance
No
0.5°C
1°C
1.5°C
2°C
2.5°C
3°C
3.5°C
4°C
4.5°C
5°C
470
Ω
change
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
0.5°C
No
0.5°C
1°C
1.5°C
2°C
2.5°C
3°C
3.5°C
4°C
4.5°C
2k
Ω
Down Change
Up
Up
Up
Up
Up
Up
Up
Up
Up
1°C
0.5°C
No
0.5°C
1°C
1.5°C
2°C
2.5°C
3°C
3.5°C
4°C
3.3k
Ω
Down
Down Change
Up
Up
Up
Up
Up
Up
Up
Up
1.5°C
1°C
0.5°C
No
0.5°C
1°C
1.5°C
2°C
2.5°C
3°C
3.5°C
5.6k
Ω
Down
Down
Down Change
Up
Up
Up
Up
Up
Up
Up
2°C
1.5°C
1°C
0.5°
No
0.5°C
1°C
1.5°C
2°C
2.5°C
3°C
8.2k
Ω
Down
Down
Down
Down Change
Up
Up
Up
Up
Up
Up
Refrigerator
2.5°C
2°C
1.5°C
1°C
0.5°C
No
0.5°C
1°C
1.5°C
2°C
2.5°C
(RCR)
10k
Ω
Down
Down
Down
Down
Down Change
Up
Up
Up
Up
Up
3°C
2.5°C
2°C
1.5°C
1°C
0.5°C
No
0.5°C
1°C
1.5°C
2°C
12k
Ω
Down
Down
Down
Down
Down
Down Change
Up
Up
Up
Up
3.5°C
3°C
2.5°C
2°C
1.5°C
1°C
0.5°C
No
0.5°C
1°C
1.5°C
18k
Ω
Down
Down
Down
Down
Down
Down
Down Change
Up
Up
Up
4°C
3.5°C
3°C
2.5°C
2°C
1.5°C
1°C
0.5°C
No
0.5°C
1°C
33k
Ω
Down
Down
Down
Down
Down
Down
Down
Down Change
Up
Up
4.5°C
4°C
3.5°C
3°C
2.5°C
2°C
1.5°C
1°C
0.5°C
No
0.5°C
56k
Ω
Down
Down
Down
Down
Down
Down
Down
Down
Down Change
Up
5°C
4.5°C
4°C
3.5°C
3°C
2.5°C
2°C
1.5°C
1°C
0.5°C
No
180k
Ω
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down Change
➧
Table of Temperature Compensation by adjusting the
resistance (difference from the current temperature)
e.g., If the refrigerator compensation resistance
(RCR) is changed from 10K (the current resistance)
to 18K (the adjustment resistance), the temperature
of the refrigerator rises 33.8°F(+1°C).
Summary of Contents for 795.75082.401
Page 10: ...GY GRIS GRAY Best Best dispenser 5 CIRCUIT DIAGRAM 10 ...
Page 11: ...GY GRIS GRAY Good Better 11 ...
Page 40: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 40 ...
Page 41: ...8 5 2 Replacement Parts List 41 ...
Page 42: ...8 5 3 PWB Assembly Display And Parts List 42 ...
Page 43: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 43 G5S 1A RY5 ...
Page 44: ... 44 ...
Page 66: ...LAST EDITION Oct 31 2005 ...