7-2-4 Fill / Park Position
1. When Ice-Removing control (Normal Ice-Removing control, Ice-Removing control for test) has completed, and the
EJECTOR is in place, this control operates the ICE SOLENOID by time check in the compressor enclosure of the
refrigerator. Then it supplies water to the ice making tray.
2. Water supply level is adjustable in levels 1-5 by pressing the water supply control Switch and fill time will be determined
by the selected level.
Water supply amount TABLE
NOTE :
Below is an example used by another vendor as an explanation of what is taking place.
- 20 -
STAGE
TIME TO SUPPLY
INDICATIONS
REMARKS
1
2
3
4
5
6 sec.
7 sec.
8 sec.
9 sec.
10 sec.
The water amount will vary depending
on the water control Switch setting, as
well as the water pressure of the
connected water line.