- 54 -
Change the
PCB
Cube mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
6
Explain to customer
1
Check the loose connection
LEVER S/W
Voltage [V]
CON2
4
th
pin ~
B(NEUTRAL)
Pushing
112~115V
Not
Pushing
0~2V
3
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
LEVER S/W
Voltage [V]
CON1
12
th
pin ~
13
th
pin
Pushing
9~12V
Not
Pushing
0~2V
Change the
PCB
CON1
4
Check the resistance value.
Is Geared Motor resistance
31.1 ~ 42.1Ω?
No
Yes
Replace
Geared Motor
Resistance [Ω]
Geared Motor
31.1 ~ 42.1
5
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1Ω?
No
Yes
Replace
Geared Motor
Resistance [Ω]
Dispenser Motor
9.9 ~ 12.1
Geared Motor
Dispenser Motor
PIN12 PIN13
CON2
Summary of Contents for 795.74092.41 Series
Page 7: ... 7 ...
Page 23: ... 23 5 CIRCUIT DIAGRAM ...
Page 24: ... 24 6 TROUBLESHOOTING ...
Page 25: ... 25 ...
Page 27: ... 27 7 3 Sub PCB P N EBR76468402 ...
Page 105: ...CASE PARTS ...
Page 106: ...CASE PARTS ...
Page 110: ...DOOR PARTS ...
Page 111: ...DISPENSER PARTS 405A 278D 402C 276B 275A 276A 276I 501A 279A 278B 500J 276J 267B 279J 281A ...