![Kenmore 721.62642 Basic Field Manual Download Page 20](http://html.mh-extra.com/html/kenmore/721-62642/721-62642_basic-field-manual_184702020.webp)
D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille.
(2) Remove mount, all.
(3) Remove outcase.
(4) Disconnect the wireleads.
(5) Remove the three screws and
Magnetron
very
carefully.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and be
sure that the gasket is in good condition.
• After replacing the magnetron, check for
microwave energy leakage with a survey meter
Check microwave energy leakage must be below
the limit of 5 mW/cm
2
. (All service adjustments
should be made for minimum microwave energy
leakage readings.)