ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Electrical connection

It is the responsibility and obligation of the consumer to 

contact a quali

fi

 ed installer to assure that the electrical 

installation is adequate and is in conformance with 

the National Electrical Code ANSI/NFPA No. 70-

latest edition, or with CSA Standard C22.1, Canadian 

Electrical Code, Part 1, and local codes and ordinances.

 

Risk of electrical shock (Failure to 

heed this warning may result in electrocution or 

other serious injury.) This appliance is equipped with 

copper lead wire. If connection is made to aluminum 

house wiring, use only connectors that are approved 

for joining copper and aluminum wire in accordance 

with the National Electrical Code and local code and 

ordinances. When installing connectors having screws 

which bear directly on the steel and/or aluminum 

fl

 exible conduit, do no tighten screws su

  ciently to 

damage the 

fl

 exible conduit. Do not over bend or 

excessively distort 

fl

 exible conduit to avoid separation 

of convolutions en exposure of internal wires.

DO NOT ground to a gas supply pipe. DO NOT 

connect to electrical power supply until appliance is 

permanently grounded. Connect the ground wire before 

turning on the power.

 (If your appliance is equipped with a 

white neutral conductor.)

This appliance is manufactured with a white neutral 

power supply and a frame connected copper wire. 

The frame is grounded by connection of grounding 

lead to neutral lead at the termination of the conduit, 

if used in USA, in a new branch circuit installation 

(1996 NEC), mobile home, recreational vehicles, where 

local code do not permit grounding trough the neutral 

(white) wire or in Canada, disconnect the white and 

green lead from each other and use ground lead to 

ground unit in accordance with local codes, connect 

neutral lead to branch circuit-neutral conductor in 

usual manner see Figure 6 or 7. If your appliance is 

to be connected to a 3 wire grounded junction box 

(US only), where local code permit connecting the 

appliance-grounding conductor to the neutral (white) 

see Figure 4 or 5.

 

NOTE TO ELECTRICIAN:

 The armored cable leads 

supplied with the appliance are UL-recognized for 

connection to larger gauge household wiring. The 

insulation of the leads is rated at temperatures much 

higher than temperature rating of household wiring. The 

current carrying capacity of the conductor is governed 

by the temperature rating of the insulation around the 

wire, rather than the wire gauge alone.

Figure 5

3-WIRE GROUNDED JUNCTION BOX

36

"

 Models with Warmer Zone

Cable from Power Supply

Black 

Wires

Junction 

Box

Cable from appliance

Ground Wire

(Bare or Green Wire)

White Wire

(Neutral)

U.L.-Listed Conduit 

Connector (or CSA listed)

Red

Wires

White Wire

(Neutral)

Where local codes permit connecting the appliance-

grounding conductor to the neutral (white) wire:
If your cooktop has a 3-wire cable to be connected to 

a 3-wire grounded junction box (see 

fi

 gure 4):

1.  Disconnect the power supply.

2.  In the circuit breaker, fuse box or junction box:

  connect appliance and power supply cable wires as 

shown in 

fi

 gure 4.

If your cooktop has a 4-wire cable to be connected to 

a 3-wire grounded junction box (see 

fi

 gure 5):

1.  Disconnect the power supply.

2.  In the circuit breaker, fuse box or junction box:

  connect appliance and power supply cable wires as 

shown in 

fi

 gure 5.

Figure 4

3-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

Black 

Wires

Junction Box

Cable from appliance

Red

Wires

U.L.-Listed Conduit 

Connector (or CSA 

listed)

Ground Wire

(Bare or Green Wire)

White Wire

(Neutral)

Summary of Contents for 318205431A

Page 1: ...el is present WARNING The corners of this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING FOR YOUR SAFETY Do not store or use gasoline...

Page 2: ...rm and the Bottom of an Unprotected Wood or Metal Cabinet 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1 8 Flame Retardant Millboard Covered With Not Less Than No 28 MGS Sheet Steel 0 015 0 4 mm Stainless Steel 0 024 0 6 mm Aluminum or 0 020 0 5 mm Copper 2 6 4 cm Min From Edge of Cutout to Front Edge of Countertop Approximate Location of Junction Box 18 45 7 cm ...

Page 3: ... 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line a 40A time delay fuse or circuit breaker is recommended DO NOT fuse neutral NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA standard C22 1 Can...

Page 4: ...disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 6 or 7 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 4 or 5 NOTE...

Page 5: ...as a 4 wire cable see figure 7 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the circuit breaker fuse box or junction box connect appliance and power supply cable wires as shown in figure 7 WARNING If connecting to a 4 wire power supply cable electrical system the appliance frame connected ground wire MUST NOT be connected to the neutral wir...

Page 6: ...f this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner Checking Operation Refer to the Use and Care Guide for operation CAUTION Do not touch cooktop glass or elements They may be hot enough to burn you Model and Serial Number Location The serial plate is located under the cooktop When ordering parts for or making i...

Page 7: ...t in oven Figure 12 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE Approx 3 7 5 cm Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of approved cooktop models 4 11 5 cm Max For typical under counter installation of an electric built in oven see ...

Page 8: ...8 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Notes ...