Kenmore 318205431A Installation Instructions Manual Download Page 1

1

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Cooktop Dimensions

IMPORTANT INSTALLATION 

INFORMATION

•  All electric cooktops run o

  a 

single phase, three-wire or four-wire 

cable, 240/208 volt, 60 hertz, AC 

only electrical supply with ground.

•  Please note minimum distance 

between cooktop and adjacent and 

overhead unprotected cabinetry is 

30" (76.2 cm).

* 30

"

 (76.2 cm) min. for unprotected cabinet.

 24

"

 (61 cm) min. for protected surface.

Figure 1

All dimensions are in inches (cm).

* Allow 2

"

 (5 cm) space below cooktop to clear the electric cable and allow for 

installation of the junction box on the wall at the back of the cooktop.

Printed in China

4

"

 X 8

"

(10.2 cm x 20.3 

cm) 

opening at the 

right rear to route 

armored cable if a 

panel is present.

WARNING

 

The corners 

of this unit are fragile. 

Carefully install the cooktop 

by its sides. When installing, 

never let the weight of the 

unit rest on any one corner. 

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

WARNING

 

FOR YOUR SAFETY: Do not store or use gasoline or other 

fl

 ammable vapors 

and liquids in the vicinity of this or any other appliance.

PRODUCT DIMENSIONS

MODEL

A. WIDTH

B. DEPTH

C

1

. HEIGHT

C

2

. HEIGHT

D. BOX WIDTH

E. BOX DEPTH

30" Ceramic Model

30¾ (78.1)

21½ (54.6)

5 (12.7)

3¼ (8.3)

29 (73.7)

19½ (49.5)

CUT OUT DIMENSIONS

MODEL

F. WIDTH

G. DEPTH

H. HEIGHT BELOW 

COOKTOP*

MINIMUM

MAXIMUM

MINIMUM

MAXIMUM

30" Ceramic Model

29¾ (75.6)

30 1/8 (76.5)

20 3/8 (51.8)

20¾ (52.7)

6 (15.2)

Cooktop Cutout Dimensions

P/N 318205431 (1311) Rev. A

English – pages 1-8

Español – pages 9-16

Français - pages 17-24

Summary of Contents for 318205431A

Page 1: ...el is present WARNING The corners of this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING FOR YOUR SAFETY Do not store or use gasoline...

Page 2: ...rm and the Bottom of an Unprotected Wood or Metal Cabinet 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1 8 Flame Retardant Millboard Covered With Not Less Than No 28 MGS Sheet Steel 0 015 0 4 mm Stainless Steel 0 024 0 6 mm Aluminum or 0 020 0 5 mm Copper 2 6 4 cm Min From Edge of Cutout to Front Edge of Countertop Approximate Location of Junction Box 18 45 7 cm ...

Page 3: ... 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line a 40A time delay fuse or circuit breaker is recommended DO NOT fuse neutral NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA standard C22 1 Can...

Page 4: ...disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 6 or 7 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 4 or 5 NOTE...

Page 5: ...as a 4 wire cable see figure 7 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the circuit breaker fuse box or junction box connect appliance and power supply cable wires as shown in figure 7 WARNING If connecting to a 4 wire power supply cable electrical system the appliance frame connected ground wire MUST NOT be connected to the neutral wir...

Page 6: ...f this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner Checking Operation Refer to the Use and Care Guide for operation CAUTION Do not touch cooktop glass or elements They may be hot enough to burn you Model and Serial Number Location The serial plate is located under the cooktop When ordering parts for or making i...

Page 7: ...t in oven Figure 12 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE Approx 3 7 5 cm Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of approved cooktop models 4 11 5 cm Max For typical under counter installation of an electric built in oven see ...

Page 8: ...8 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Notes ...