Plan where and how the ductwork will be installed.
If using 7” or 8” round ducts, use a transition . Use 2” metal foil duct tape to seal duct joints.
INSTALL DUCTWORK
TYPICAL DUCTWORK
ROOF CAP
7” or 8” ROUND
or 3¼” x 10”
RECTANGULAR
ELBOW
24” TO 30” ABOVE
COOKING SURFACE
WALL CAP
HOOD
CABINET or
DECORATIVE FLUE
HH0224A
7” or 8” ROUND
or 3¼” x 10” DUCT
12”
PREPARE THE HOOD LOCATION
The minimum hood distance above cooktop must not be
less than 24”. A maximum of 30” above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
CEILING
CABINET,
DECORATIVE FLUE
STANDARD 36”
HIGH COOKTOP
TOP OF WOOD
MOUNTING STRIP
A
+ 2’’
HOOD
A
HH0226A
MINIMUM DISTANCE BETWEEN
THE HOOD AND COOKTOP: 24’’
RECOMMENDED MAXIMUM
DISTANCE BETWEEN THE HOOD
AND COOKTOP: 30’’
MINIMUM AND MAXIMUM DISTANCE OVER
COOKTOP
W
arr
anty
Saf
ety
Cle
aning
Oper
ation
Installation
Ser
vice P
ar
ts
NON-DUCTED INSTALLATION
For non-ducted installation, a recirculation kit 55673 or 55683 (sold seperately) must be installed. See installation
instructions included with the non-duct kit 55673 or 55683.