10
HORIZONTAL DISCHARGE INSTALLATION
All hoods are factory shipped with the blower mounted for a vertical discharge con
fi
guration. For a horizontal
discharge con
fi
guration, disassemble the blower from the inner top of the hood and mount it to the inner back panel
of the hood.
1. Using a 5/16" socket, remove all blower
mounting screws from the inner top of
the hood. Keep the screws for further use.
2. Slide the blower to disengage its
fl
ange from the
retaining
bracket.
3. Rotate the blower and engage its
fl
ange in
the back wall retaining bracket.
4. Using a 5/16" socket and the screws
previously removed, secure the blower to the
hood.
HD0282
R
IGHT
SIDE
MOUNTING
SCREWS
LOCATION
HD0270
R
IGHT
SIDE
MOUNTING
SCREWS
LOCATION
HD0288
HD0269
L
EFT
SIDE
MOUNTING
SCREWS
LOCATION
L
EFT
SIDE
MOUNTING
SCREWS
LOCATION
HD0289