Residen al Hybrid Electric Heat Pump Water Heater Use and Care Guide
•
19
INS
TALLA
TION
Post Installa on Review
1
Understand how to use the
User Interface Module to set
the various modes and
func ons.
2
Hybrid Mode is the recom-
mended Opera ng Mode.
Understand the various
Opera ng Modes and which mode may
be best, based on ambient temperature
and hot water demands.
3
Understand the importance of
rou ne inspec on/ mainte-
nance of the condensate drain
pan and lines. This is to prevent any
possible drain line blockage resul ng in
the condensate drain pan over
fl
owing.
NOTE:
If water is coming from the
over
fl
ow slot of the condensate drain
access cover, this indicated that both
condensate drain lines may be blocked
and immediate ac on is required.
Overflow Slot
Drain Access Cover
Primary Drain
Secondary Drain
Figure 25 -
Condensate Drain Access
Cover
4
To maintain op mal opera on,
check, remove and clean the
air
fi
lter as needed.
5
The Installa on Instruc ons
and Use and Care Guide should
be kept with the water heater
for reference.
Water Temperature Ad-
justment
The water temperature can be
adjusted from 95°F / 35°C to 150°F /
65.5°C. Use the Up and Down Bu ons
on the front panel to
set the desired temperature (
fi
gure 26,
page 21). The se ng temperature will
blink on the display, press Mode/Enter
bu on to con
fi
rm.
The water temperature can be adjusted
quickly by pressing the “Temperature
Up” bu on and holding for three
seconds.
NOTE:
Before a emp ng to adjust
the thermostat, read the “Water
Temperature Regula on” sec on. If
the instruc ons are not clear, contact a
quali
fi
ed person.
NOTE:
For increased water demand,
switching (temporarily) to Hybrid
Mode or Electric Mode will decrease
the recovery/re-heat me. Be sure to
switch back to the desired opera onal
mode when
fi
nished.
Opera ng Mode De-
scrip ons
The opera ng modes can be changed
sequen ally by pressing the Mode/
Enter bu on (Figure 26, page 21). The
Opera on Mode Indica on Light will
turn on when the relevant mode is
selected.
This unit is equipped with technology
that senses the hot water demand
from the unit. While in E
ffi
ciency or
Hybrid mode, during normal usage,
the unit will operate the heat pump
for maximum e
ffi
ciency. In the Hybrid
mode during periods when the water
usage is above normal, this unit
has the ability to use one element
(upper or lower) and the heat pump
simultaneously to help improve
recovery. This transi on is seamless
and will go unno ced.
Efficiency Mode -
Provides the highest efficiency and
lowest cost operation by using only
the heat pump for heating. Recovery
time and efficiency will vary with
ambient temperature and relative
humidity. Efficiency will be greatest,
and recovery quickest, when both
are high. At lower temperatures and
relative humidity levels, efficiency
will be lower and recovery will take
longer. Heat pump operation is allowed
between 45°F / 7.2°C to 120°F / 48.8°C
ambient temperature. At ambient
temperatures lower than 45°F / 7.2°C
and greater than 120°F / 48.8°C, the
heat pump will not operate. Similarly,
if the water temperature in the tank is
less than 59°F / 15°C, the heat pump
will not operate. The unit will operate
in electric mode until ambient air and
water temperatures return to the safe
operating range of the heat pump.
Hybrid Mode -
This is the default, recommended
setting, combining high energy
efficiency with reduced recovery time.
This mode uses the heat pump as the
primary heating source. One of the
heating elements (upper or lower)
will provide supplementary heating if
demand exceeds a predetermined level
so that the set point temperature can
be recovered more quickly.
Electric Mode -
The water heater functions as a
conventional electric unit, relying on
only the elements for heat. This mode
may be useful in periods of increased
hot water demands. Electric Mode will
remain for 48 hours before reverting
back to default mode setting.
INSTALLATION
Summary of Contents for 153.592500
Page 35: ......