Wiring 

You must provide all wiring of the proper size outside of the 

water heater. You must obey local codes and electric company 

requirements when you install this wiring.

If you are not familiar with electric codes and practices, or if 

you have any doubt, even the slightest doubt, in your ability 

to connect the wiring to this water heater, obtain the service 

of a competent electrician. Contact your Sears salesperson 

to arrange for a professional electrician.

WIRING DIAGRAMS

 

C-2 C-2

 

STANDARD WIRING FOR 

STANDARD WIRING FOR

 

SINGLE ELEMENT 240 VOLT 

SINGLE ELEMENT 120 VOLT

FIGURE 11.

WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: 
This water heater is equipped for one type voltage only. 
Check the rating plate near the bottom access panel for 
the correct voltage. DO NOT use this water heater with 
any voltage other than the one shown on the model rating 
plate. Failure to use the correct voltage can cause problems 
which can result in DEATH, SERIOUS BODILY INJURY, OR 
PROPERTY DAMAGE. If you have any questions or doubts 
consult your electric company.
If wiring from your fuse box or circuit breaker box was 
aluminum for your old water heater, replace it with copper 
wire. If you wish to reuse the existing aluminum wire, have 
the connection at the water heater made by a competent 
electrician. Contact your Sears salesperson to arrange for 
a professional electrician.      

1.  Provide a way to easily shut off the electric power when 

working on the water heater. This could be with a circuit 
breaker or fuse block in the entrance box or a separate 
disconnect switch.

2.  Install and connect a circuit directly from the main fuse or 

circuit breaker box. This circuit must be the right size and 
have its own fuse or circuit breaker. Refer to the chart in 
the “Product Specifications” section for the correct size 
wire and fuse or circuit breaker.

3.  If metal conduit is used for the grounding conductor:

A.  The grounding electrode conductor shall be of copper,

aluminum, or copperclad aluminum. The material shall 
be of one continuous length without a splice or joint.

B.  Rigid metal conduit, intermediate metal conduit, or  

electrical metallic tubing may be used for the grounding  
means if conduit or tubing is terminated in fittings 
approved for grounding.

C.  Flexible metal conduit or flexible metallic tubing shall 

be permitted for grounding if all the following conditions 
are met:

• The length in any ground return path does not 

exceed 6 feet.

•  The circuit conductors contained therein are protected 

by overcurrent devices rated at 20 amperes or less.

• The conduit or tubing is terminated in fittings 

approved for grounding.

For complete grounding details and all allowable exceptions, 
refer to the current edition of the NEC - National Electrical 
Code NFPA 70.
4.  A standard 1/2” conduit opening has been made in the 

water heater junction box for the conduit connection.

5.  Use wire nuts and connect the power supply wiring to the 

wires inside the water heater’s junction box.

6.  The water heater must be electrically “grounded” by the 

installer. A green ground screw has been provided on the water 
heater’s junction box. Connect ground wire to this location.

7.  Replace the wiring junction cover using the screw provided.

WIRING CONNECTIONS

FIGURE 12.

Summary of Contents for 153.316050

Page 1: ...ater OWNER Retain these instructions for future reference Si no puede leer o entender el inglés y necesita el manual de instrucciones en español puede solicitarlo al 1 800 821 2017 NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES No hacer caso de esta advertencia podría originar lesiones graves o mortales ADVERTENCIA P N 185775 003 0313 Sears Brands Management...

Page 2: ... in accordance with the service guidelines provided by the manufacturer SAFE INSTALLATION USE AND SERVICE Your safety and the safety of others is extremely important in the installation use and servicing of this water heater Many safety related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard Read and obey ...

Page 3: ...3 GENERAL SAFETY ...

Page 4: ...or years of dependable op eration But like all products it may require preventive maintenance or repair from time to time That s when having a Master Protection Agreement can save you money and aggravation The Master Protection Agreement also helps extend the life of your new product Here s what the Agreement includes Parts and labor needed to help keep products operating properly under normal use...

Page 5: ...Code NFPA 70 This publication is available from your local government or public library or electric company or by writing Underwriters Laboratories Inc 333 Pfingsten Road Northbrook IL 60062 3 If after reading this manual you have any questions or do not understand any portion of the instructions call Sears Service Center 4 Carefully plan your intended placement of the water heater INSTALLATION OR...

Page 6: ...153 316060 YES YES YES YES PLUGGED YES PLUGGED 153 316070 YES YES YES YES PLUGGED YES PLUGGED 153 316332 YES YES YES NO NO 153 326070 YES YES YES YES PLUGGED YES PLUGGED DIMENSIONS IN INCHES mm TANK CAPACITY ELEMENT WATTAGE HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED PLUMBING AND ELECTRICAL WORK ARE REQUIRED Examine the location to ensure the water heat...

Page 7: ...TIONS PIPE WRENCH GARDEN HOSE 6 FOOT TAPE HACKSAW TUBING CUTTER PROPANE TORCH ROLL OF EMERY CLOTH 3 4 19 mm WIRE BRUSH 1 2 13 mm WIRE BRUSH ROLL OF LEAD FREE SOFT SOLDER SOLDER FLUX Materials Needed To simplify the installation Sears has available the installation parts shown below You may or may not need all of these materials depending on your type of installation EXPANSION TANKS FOR THERMAL EXP...

Page 8: ... If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain va...

Page 9: ...ve with an insulation blanket Do not cover the instruction manual Keep it on the side of the water heater or nearby for future reference Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels FIGURE 7 Mineral buildup or sediment may have accumulated in the old water heater This causes the water heater to be much heavier than normal and this resi...

Page 10: ...ded to control thermal expansion Contact the local utility or Sears Service Center on how to control this situation See Thermal Expansion Also the water supply pressure should not exceed 80 psi If this occurs a pressure reducing valve with a bypass should be installed in the cold water inlet line This should be placed on the supply to the entire house in order to maintain equal hot and cold water ...

Page 11: ... is installed into the T P valve discharge opening per the instructions in this manual 4 Locate the hot water outlet cold water inlet pipes to the water heater 5 Locate the slit running the length of a section of pipe insulation 6 Spread the slit open and slip the insulation over the cold water inlet pipe Apply gentle pressure along the length of the insulation to ensure that it is fully seated ar...

Page 12: ... relief valve and the discharge pipe Must terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building Must not have any shut off valve between the relief valve and tank nor in the discharge pipe The temperature pressure relief valve must be manually operated at le...

Page 13: ...n the entrance box or a separate disconnect switch 2 Install and connect a circuit directly from the main fuse or circuit breaker box This circuit must be the right size and have its own fuse or circuit breaker Refer to the chart in the Product Specifications section for the correct size wire and fuse or circuit breaker 3 If metal conduit is used for the grounding conductor A The grounding electro...

Page 14: ...injury The thermostat is adjustable if a different water temperature is desired Read all warnings in this manual and on the water heating before proceeding TABLE 1 TEMPERATURE SETTINGS It is recommended that the dial be set lower whenever possible Temperature Time to Produce 2nd 3rd Setting Degree Burns on Adult Skin VERY HOT approx 160 F 71 C About 1 2 second C approx 150 F 66 C About 1 1 2 secon...

Page 15: ...N power Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be manually operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 the water manually discharged will not cause any property damage or bodily injury The water may be extremely hot FIGU...

Page 16: ... Put plastic terminal cover back in place 9 Replace the insulation to cover the thermostat 10 Replace access panel then turn the electric power on Element Cleaning Replacement To remove the element from your tank in order to clean or replace it 1 Before beginning turn OFF the electric power supply to the water heater FIGURE 16 HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servici...

Page 17: ... the Repair Parts List Chart Place the new element gasket on the thread side of the cleaned or new element and screw into tank securing tightly using an element wrench FIGURE 23 11 Close the water heater drain valve by turning the handle to the right clockwise 12 Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use ...

Page 18: ...glass lined tank from corrosion Adverse water quality hotter water temperatures high hot water usage hydronic heating devices and water softening methods can increase the rate of anode rod depletion Once the rod is depleted the tank will start to corrode eventually developing a leak Certain water conditions will cause a reaction between the anode rod and the water The most common complaint associa...

Page 19: ...t Up Conditions THERMAL EXPANSION As water is heated it expands thermal expansion In a closed system the volume of water will grow As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion Thermal expansion can cause premature tank failure leakage This type of failure is not covered under the limited warranty Thermal expansion can also cause int...

Page 20: ...node replacement and chlorination of the tank are not covered by the water heater s limited warranty If smelly water persists after anode replacement and chlorination treatment you should consider chlorinating or aerating your water supply Do not remove the anode leaving the tank unprotected By doing so all warranty on the water heater tank is voided AIR IN HOT WATER FAUCETS HYDROGEN GAS Hydrogen ...

Page 21: ...ur water heater is ON 3 Check for loose or blown fuses in your water heater circuit Circuit breakers weaken with age and may not handle their rated load and should be replaced 4 Make certain the disconnect switch if used is in the ON position 5 Check to see the electric service to your house has not been interrupted If this is the case contact the electric company 6 Is the thermostat set to the de...

Page 22: ...hermal expansion or high water pressure in your area C The temperature pressure relief valve may be leaking at the tank fitting D The element may be leaking at the tank fitting E Water from drain valve may be due to the valve being opened slightly F The drain valve may be leaking at the tank fitting G Water in the water heater bottom or on the floor may be from condensation loose connections or th...

Page 23: ...9006296 9003663 9003663 18 Plug 9001437 9001437 9001437 9001437 Now that you have purchased this water heater should a need ever exist for repair parts or service simply contact any Sears Service Center or call 1 800 4 MY HOME 1 800 469 4663 Be sure to provide all pertinent facts when you call or visit If the parts you need are not stocked locally your order will be electronically transmitted to a...

Page 24: ...MATION Model Number Part Number Serial Number Part Description THIS IS A REPAIR PARTS LIST NOT A PACKING LIST Also available at most hardware stores Not illustrated KENMORE COMPACT ELECTRIC WATER HEATERS REPAIR PARTS LIST MODEL NO S 153 316332 30 Gallon Key No Part Description 153 316332 1 Access Panel 9003900 2 Anode Rod 9003944 3 Drain Valve 9000058 4 Drain Valve Washer 17 32 x 13 64 x 1 8 Thick...

Page 25: ...25 NOTES ...

Page 26: ...26 NOTES ...

Page 27: ...27 NOTES ...

Page 28: ...d owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call anytime for the location of your nearest Sears Parts R...

Reviews: