REMOVING CLOGS
CLEANING EXTERIOR AND ATTACHMENTS
CANISTER CARE
HOSE
When the hose is clogged with dust, remove
it in the following manner:
1.
Pull out the handle by turning the
removal ring in either direction.
2.
Remove any clogs in the handle. Shake
the hose to remove any clogs.
3.
Insert the handle in place and return the
ring to its original position.
4.
Check the dust filter cover in the dust bin
and clean if necessary (See
CLEANING
DUST BIN
, page 14).
5.
Check the secondary filter and clean if
necessary (See
CLEANING SECONDARY
FILTER
, page 17).
6.
Check exhaust filter and replace if
necessary (See
REPLACING EXHAUST
FILTER
, page 16).
CAUTION
Product Damage Hazard
Do not use the hose without the handle in
place. If the hose is used without the
handle, the hose will bend excessively,
causing it to crack.
CAUTION
Do not use attachments if they are wet.
Attachments used in dirty areas, such as
under a refrigerator, should not be used
on other surfaces until they are washed.
They could leave marks.
1.
Turn off and unplug vacuum cleaner.
DO
NOT drip water on vacuum cleaner.
2.
To clean exterior, or to reduce static
electricity and dust build-up, wipe outer
surface with a clean, soft cloth that has
been dipped in a solution of mild liquid
detergent and water, then wrung dry. Wipe
dry after cleaning.
Handle
Removal
Ring
TURBINE UNIT
The turbine unit has a clean-out port for
removing clogs.
1.
Press latches inward and lift off clean-out
port cover.
2.
Remove any debris or build-up.
3.
Reinstall cover. Make sure it is
completely secured in place. A noticeable
“click” should be heard.