background image

 

Page | 5  

Save This Manual for Future Reference 

Installation  

 

Step 1:  
 

Cut and remove the two plastic banding and any shrink wrap material, remove top from crate 
packaging & remove components.  

 
Step 2:  
                     

Place the Work Surface on its top on a clean and sturdy working area. Locate the two leg 
assemblies and 16 Pan Head Screws. Install the screws 6 into the inside of each Leg Assembly 
and 2 on the outer side. 
 
 

 
 
 
 
 
 
 
 
 
 
 
Step 3:  
                     

Locate the Gussets. Place the bottom of the slotted end of the Gusset in to the slot guide of the 
Leg Assembly, Locate 8 Pan Head Screws. Install Screws through the Gusset and into the Work 
Surface  
 
 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for ESDW-6030-1000

Page 1: ...Page 1 Save This Manual for Future Reference Owner s Manual Part Number ESDW 6030 1000 For Your Safety Read and understand the entire manual before use 60 ESD WORKBENCH...

Page 2: ...ual accurate and complete However Kendall Howard LLC makes no representations or warranties of any kind expressed or implied about whether the use of products contained herein would infringe any right...

Page 3: ...ifications Overall Dimensions 60 Wide x 30 Deep x 30 Tall at lowest setting Worksurface Dimensions 30 Deep x 60 Long Weight 132 lbs 290 kg Workbench Support Color Gloss Black Powder Coat Worksurface C...

Page 4: ...face 60 x 30 1 Leg Assembly 2 Part Number A 1081 Part Number A 1075 Cross Bar 2 Gusset 2 Part Number A 1078 Part Number A 1080 Pan Head Screw 40 ESD Grounding Boot 1 Part Number HW PHS 006 Part Number...

Page 5: ...e Work Surface on its top on a clean and sturdy working area Locate the two leg assemblies and 16 Pan Head Screws Install the screws 6 into the inside of each Leg Assembly and 2 on the outer side Step...

Page 6: ...s head screw from the Ground Boot place the lever stem through the bottom of the Grounding Boot latch the top of the Grounding Boot strip and install the ground wire between the boot halves Reinstall...

Page 7: ...metal surfaces leg levelers or on the work surface The soap may leave a residue that will insulate the surface from ESD grounding Wipe down all cleaned surfaces with a lint free soft cloth Leg levele...

Page 8: ...Check the RTG value of 10 10 Ohms resistance from the common ground on the work surface to the conductive aluminum boot If this test passes replace the ESD surface If this RTG value fails proceed to t...

Page 9: ...eir authorized representatives in the performance of work to correct defects in Kendall Howard components Accordingly Kendall Howard may utilize third parties in the performance of Warranty work inclu...

Reviews: