10
Figure 21
Figure 22
12. ATTACHING THE
LIGHT PLATE
NOTE:
Before starting installation, disconnect the
power by turning off the circuit breaker or removing
the fuse at fuse box. Turning power off using the
fan switch is not sufficient to prevent electric shock.
Step 1.
Raise and hold the light kit close to the
mounting plate and proceed to do the wire
connections, follow the same procedure with the
black wire connectors. Attach the light kit to the
mounting plate by using the four (4) screws
provided that are preinstalled on the mounting
plate. (Fig. 21)
13. ATTACHING THE
LIGHT BULB AND
GLASS SHADE
WARNING:
Shut off the power supply before
removing or replacing lamp. In handling of halogen
bulb, care should be taken not to touch it with your
bare hands. Oil residue will shorten the life of the
halogen bulb. If you accidentally come into contact,
wipe thoroughly with a clean, lint-free, cotton cloth.
Allow the bulb to cool off for 10 minutes before
changing the bulb. Use light bulb in accordance
with the fan's specification. TO REDUCE THE RISK
OF FIRE DO NOT EXCEED MAXIMUM WATTAGE
RATING.
Step 1.
Install 100W halogen bulb J-type (included).
(Fig. 22)
Step 2.
Raise glass shade up against bottom of fan
housing and secure it to fan by twisting glass
clockwise until snug. DO NOT OVERTIGHTEN.
(Fig. 22)
Mounting
plate
Connection plugs
Light plate
Screws
Glass shade
Bulb
Light plate