![Kemppi MXF 63 Operating Instructions Manual Download Page 22](http://html1.mh-extra.com/html/kemppi/mxf-63/mxf-63_operating-instructions-manual_663147022.webp)
EN
5.2 PF 63 and PF 65 control panel button functions
1.
3.
2.
4.
5. 6.
7.
8.
9.
10.
11.
W003712
PF 65
5.2.1 ON/OFF button
1.
Short Press: Panel returns to default display.
Long Press: When welding panel (PF 65) is ON => Welding panel is turned OFF. When welding
panel (PF 65) OFF => welding panel is turned ON and Setup Panel (P65) turns ON and selects
automatically that welding panel (WF#).
5.2.2 Dynamics button
2.
Short Press: Dynamics setting if welding process is MIG/Synergic MIG. ArcForce setting if
welding process is MMA. Forming Pulse setting if welding process is Wise-Root/WiseThin.
Long Press: Wire Feeder number selection (WF#). If more than one wire feeder is connected to
system WF number selection must be made. Every wire feeder must be different WF number.
5.2.3 Gas Test button
3.
Gas Test function.
Pressing the button will show the gas test time. Gas test time can be adjusted by using the
pulse encoder.
Gas test will proceed after time adjustment is complete (short delay).
Gas test can be stopped by pressing any button.
(Gas test can also be started by pressing the Gas Test button inside the wire spool cabinet.)
FastMig MXF 63, 65, 67
20
Summary of Contents for MXF 63
Page 2: ......
Page 3: ...OPERATING MANUAL English ...