seTup-FunCTiOns
SETUP-function
Display
*C = Common: applies to all memory channels
Factory setting with a grey background
Upslope current dependency
(*C)
A1
ON
The upslope time is determined by the current.
OFF
The upslope time remains as set.
Downslope current
dependency (*C)
A2
ON
The downslope time is determined by the current.
OFF
The downslope time remains as set.
TIG Antifreeze (*C)
A3
ON
TIG Antifreeze on.
OFF
TIG Antifreeze off.
MMA Antifreeze (*C)
A4
ON
MMA Antifreeze on.
OFF
MMA Antifreeze off.
VRD (*C)
A7
ON
VRD mode: idle voltage < 35 V
OFF
Normal idle voltage (3000: 63 V, 3003: 58 V)
2T downslope cut off
A8
ON
In 2T mode, cut off the downslope with a quick push of the start
button.
OFF
Quick push has no effect.
Tacking automatics
A9
ON
If welding has lasted less than 3 seconds, no downslope when
welding is stopped.
OFF
Tacking automatics off.
Limitation of rate of current
rise with high currents
A10
ON
If the current is over 100 A and UpSlope is 0.0 sec., there is a 0.2-
second slope from half the welding current.
OFF
Current rises directly to indstillet værdi.
MMA/TIG method selection
with remote control (C*)
A12
ON
TIG = the start of remote control scale.
MMA = the end of the scale.
OFF
Remote control as a normal current regulator.
SearchArc On/Off
A13
ON
SearchArc on.
OFF
SearchArc off.
Current freeze function
A14
ON
During the slope, the current can be ‘frozen’ at a certain level (4T
and Minilog) by pushing the start button.
OFF
Freeze function off.
Memory channel selection with
Plus/Minus buttons (C*)
A15
ON
The Plus/Minus buttons on the remote control RTC20 can be used
to select the memory channel.
OFF
The buttons adjust the current.
Activation of the Plus/Minus
buttons (C*)
A16
ON
The Plus/Minus remote control (RTC20) is always active.
OFF
The Plus/Minus remote control is active only when selected by
pressing the REMOTE button.
Water cooler flow guard (C*)
A17
ON
Flow guard on.
OFF
Flow guard off.
Water cooler automatic control
(C*)
A19
ON
Automatic control on.
OFF
Water cooler runs constantly.
Water cooler temperature
guard (C*)
A20
ON
Water cooler temperature guard selected.
OFF
Temperature guard off.
Automatic remote control
device recognition (C*)
A21
ON
Automatic recocnition on, control cannot be selected if it is not
connected.
OFF
Automatic recocnition On/Off. Controller can be selected even if it
is not connected.
Tail arc
A22
ON*
Tail arc on. * 4T LOG
OFF**
Tail arc off. ** MINILOG
18
M
ast
er
Tig MLS 3000, 3003 A
CDC / © Kemppi O