TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC
SELECTION OF REMOTE CONTROL UNIT
1
. Turn off the machine.
2
. Press the
REMOTE
key and at the same time turn the machine on; the display
will show the text
rEn 01
. The machine is now selected to use for hand held
remote control units (C 100C, C 100D, or C 100AC).
3
. Turn the current adjustment knob so that the display shows
rEn 02
.
The machine is now selected to use foot controlled remote unit (C 100F).
4
. Press the
REMOTE
key so that the setting is saved in the memory.
CALIBRATION OF THE PANEL
It is possible to calibrate the current meter of the Mastertig ACDC in DC -
and DC + at two different points, 10 A and 100A. If you want to calibrate the
current setting of the machine you will need a shunt resistor, loading bench
and multimeter to monitor real current value.
1.
First set machine polarity to DC - and note the meter readings when set
value is 10 A and 100 A. Repeat this process for DC + polarities
2
. Turn off the machine.
3
. Press the
POST GAS
key and at the same time turn the machine on.
4
. Press the
BROKEN ARC
key; display will show text
CU1 010
. Now you
can feed in, by the current adjustment knob, the real measured value for
DC - 10 A.
5
. By pressing the
REMOTE
next time display will show text
CU2 100
,
you can
now feed in the measured DC -100 A value.
6
. Repeat same with DC +,
CU3 010
is for DC + 10 A and
CU4 100
is for
DC + 100 A.
7
. Press the
POST GAS
key so that the calibration setting is saved in the
memory.
8
. Check the corrected values from the panel display.
Summary of Contents for MASTERTIG AC/DC 2500W
Page 1: ...TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC MACHINES ...
Page 15: ......
Page 16: ......
Page 17: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......