TABLE 2. CONNECTOR XW101 IN MASTERTIG ACDC
PIN NUMBER
SIGNAL VALUE
DESCRIPTION
A
3.5 VAC start not active
0 V start is active
Torch start switch
B
3.5 VAC start not active
0 V start is active
Torch start switch
C
-
-
D
-
-
TABLE 3. CONNECTOR XW102 IN MASTERTIG ACDC
PIN NUMBER
SIGNAL VALUE
DESCRIPTION
A
-
-
B
30 VAC
Operating voltage for external
equipment, fuse 0.8 A
C
30 VAC
Operating voltage for external
equipment, fuse 0.8 A
D
-
-
E
+5 VDC
Voltage reference of remote control
(upper end of the potentiometers)
F
0 V
GND (lower end of potentiometers)
G
-
-
H
0 - +5 VDC
Set value for power source
I
+2 VDC=
TIG
+5 VDC=
MMA
Selection of characteristic
TIG
/
MMA
curve
J
-
-
TABLE 4. OVER AND UNDER VOLTAGE LIMITS, (
WHEN
OCV)
SUPPLY VOLTAGE
LOWER LIMIT
UPPER LIMIT
MASTERTIG ACDC 1600
230 VAC
165 VAC
270 VAC
MASTERTIG ACDC 2500
230 VAC
175 VAC
270 VAC
400 VAC
300 VAC
460 VAC
460 VAC
340 VAC
530 VAC
MASTERTIG ACDC 3500
400 VAC
365 VAC
460 VAC
Summary of Contents for MASTERTIG AC/DC 2500W
Page 1: ...TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC MACHINES ...
Page 15: ......
Page 16: ......
Page 17: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......