Master 315
Operating manual - EN
To adjust settings:
1.
Go to the
Settings
view.
2.
Turn the control knob (1) to browse through the settings groups and parameters.
3.
Select a parameter to be adjusted or changed by pressing the control knob button (1).
4.
Adjust or change the setting by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
Some of the settings are e.g. current mode and welding process specific and are visible or not visible in the settings
menu accordingly.
Common welding settings:
Parameter
Value
Note
Welding process
TIG / MMA (Default = TIG)
Selecting a welding process changes automatically to the
last active channel for the selected process.
Current limit min
TIG: 2 A / MMA: 8 A, step 1 A
*
Current limit max
TIG: power source's nominal value
MMA: power source's max.
MMA current, step 1 A
*
Remote control mode
OFF / Remote (Default = OFF)
When a remote control is selected, the welding current
adjustment on the control panel is disabled.
Remote control min
Min = “Current limit min”, Max = “Current
limit max”
Remote control max
Min = “Current limit min”, Max = “Current
limit max”
Wireless remote
Pairing starts automatically when selected
New pairing information replaces the old information.
Pairing status is shown as the settings value.