Kemppi KEMPARC COOL 10 Operating Manual Download Page 5

EN

1. 

preFACe

1.1 

generAl

Congratulations on your choice of the Kemparc™ Cool 10 cooling unit. 

Reliable and durable, Kemppi products are affordable to maintain, and they 

increase your work productivity. 
This user manual contains important information on the use, maintenance 

and safety of your Kemppi product. The technical specifications of the device 

can be found at the end of the manual. Please read the manual carefully 

before using the equipment for the first time. For your safety and that of your 

working environment, pay particular attention to the safety instructions in 

the manual.
For more information on Kemppi products, contact Kemppi Oy, consult an 

authorised Kemppi dealer, or visit the Kemppi Web site at www.kemppi.com.
The specifications presented in this manual are subject to change without 

prior notice.

NOTE!  

Items in the manual that require particular attention in order to minimise 

damage and personal harm are indicated with this symbol. Read these sections 

carefully and follow their instructions.

1.2 

sAFetY instruCtiOns

Kemppi welding devices conform to international safety standards. Safety 

is an important issue in equipment design and manufacturing. Therefore, 

Kemppi welding solutions are unparalleled in safety. There are, however, 

always certain hazards involved in using welding equipment. Therefore, to 

ensure your personal safety and the safety of your working environment, 

carefully read the safety instructions below and respect them.

use of personal protective equipment

•  The arc and its reflecting radiation damage unprotected eyes. Shield 

your eyes and face appropriately before you start welding or observe 

welding. Also note the different requirements for the darkness of the 

screen in the mask as the welding current changes.

•  The arc radiation and spatters burn unprotected skin. Always wear 

protective gloves, clothing and footwear when welding.

•  Always wear hearing protection if the ambient noise level exceeds the 

allowable limit (e.g., 85 dB).

KempA

rc™

 C

OOL

 10

 / 

©

 Kemppi

 O

/ 0725

Summary of Contents for KEMPARC COOL 10

Page 1: ...g Dansk Operating manual English Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Français Manual de instrucciones Español Instrukcja obsługi Polski Инструкции по эксплуатации По русски 1920140 0725 FI SV NO DA EN DE NL FR ES PL RU KEMPARC COOL 10 ...

Page 2: ......

Page 3: ...EN Operating manual English KempArc COOL 10 Kemppi Oy 0725 ...

Page 4: ...ling the equipment 7 2 4 2 Main parts of cooling unit 8 2 5 Preparing for operation 8 2 6 Cooler operation 9 2 7 Overheat signal lamp 9 2 8 Storage 9 3 Maintenance 9 3 1 Daily maintenance 10 3 2 Regular maintenance 10 3 2 1 Every sixth months 10 3 2 2 Maintenance by agreement 10 3 3 Disposal of the machine 10 4 Trouble shooting 11 5 TECHNICAL DATA 11 6 WARRANTY POLICY 12 KempArc COOL 10 Kemppi Oy ...

Page 5: ...mage and personal harm are indicated with this symbol Read these sections carefully and follow their instructions 1 2 Safety Instructions Kemppi welding devices conform to international safety standards Safety is an important issue in equipment design and manufacturing Therefore Kemppi welding solutions are unparalleled in safety There are however always certain hazards involved in using welding e...

Page 6: ... safety Welding is always classified as hot work so pay attention to fire safety regulations during welding and after it Remember that fire can break out from sparks even several hours after the welding work is completed Protect the environment from welding spatter Remove flammable materials such as flammable fluids from the welding vicinity and supply the welding site with adequate fire fighting ...

Page 7: ...e fumes Ensure sufficient supply of fresh air particularly in closed spaces You can also ensure the supply of clean and sufficient breathing air by using a fresh air mask Take extra precautions when working on metals or surface treated materials containing lead cadmium zinc mercury or beryllium Transportation lifting and suspension Never pull or lift the machine by the welding torch or other cable...

Page 8: ...s A equipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system The machine may interfere with sensitive home electronic devices Gas bottles and pneumatic devices Adhere to the instructions for handling pneumatic devices and gas bottles Make sure that gas bottles are used and stored in properly ventilated spaces A leakin...

Page 9: ...here is enough space for cooling air circulation in front of and behind the machine 2 3 Serial number The serial number of the machine is marked on the machine CE marking Identificating the serial number is the only proper means of maintaining and identifying parts for a specific product It is important to make correct reference to the serial number of the product when making repairs or ordering s...

Page 10: ...contact with skin or eyes In case of injury seek for medical advice See also 2 4 2 Main parts of cooling unit 1 Connect the mains voltage and control connectors of the cooler unit to the corresponding connectors on the base of the power supply The connection can be established through the base of the power supply when the devices are separated or through the right side of the KempArc Cool 10 coole...

Page 11: ...eck the tank liquid level regularly and fill in liquid if necessary If the liquid flow is blocked a hose is blocked or folded or the container has ran out of liquid the welding is stopped and error code Err 5 appears on the KempArc panel 2 7 Overheat signal lamp The overheat signal lamp is lighting when temperature control of the machine has detected cooling water overheat The ventilator cools dow...

Page 12: ... defect parts 3 2 2 Maintenance by agreement Authorised Kemppi service agents perform regular maintenance by agreement During the maintenance the machine is cleaned and checked for faults The functionality of all parts is tested and the possible faults are repaired 3 3 Disposal of the machine Do not dispose of electrical equipment with normal waste In observance of European Directive 2002 96 EC on...

Page 13: ...ed For further information and assistance contact your nearest Kemppi service workshop 5 TECHNICAL DATA Cooling unit KempArc Cool 10 Connection voltage 24V DC Connection capacity 100 ED 50W Cooling power 1 kW Start pressure max 450 kPa Cooling liquid 20 40 etanol water Reservoir volume ca 3 l Overall dimension length 570 mm width 230 mm height 280 mm Weight 11 kg Operating temperature range 20 40 ...

Page 14: ...commodation related to warranty service The warranty does not cover welding torches and their consumables feeder drive rolls and feeder guide tubes Direct or indirect damage caused by a defective product is not covered under the warranty The warranty becomes void if modifications are made to the machine that are not approved by the manufacturer or if non original spare parts are used in repairs Th...