EN
4.
trOuble shOOting
See also 2.7. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
• Check water circulation.
• Check that there is enough free space behind the machine for cooling air
circulation.
error code err 5 on the KempArc panel
• Check the liquid hoses for damages.
• Remove any hose blockages.
• Check water circulation, add liquid if needed.
For further information and assistance, contact your nearest Kemppi service
workshop.
5.
teChniCAl DAtA
Cooling unit KempArc™ Cool 10
Connection voltage
24 V DC
Connection capacity
100 % ED
50 W
Cooling power
1 kW
Start pressure, max.
450 kPa
Cooling liquid
20 % - 40 % etanol/water
Reservoir volume
ca. 3 l
Overall dimension:
length
570 mm
width
230 mm
height
280 mm
Weight
11 kg
Operating temperature range
-20 … +40 °C
Storage temperature range
-40 … +60 °C
Degree of protection
IP 23 S
The products meet the conformity requirements of CE-marking.
11
KempA
rc™
C
OOL
10
/
©
Kemppi
O
y
/ 0725