15
© Kemppi Oy / 1418
EN
5.2 Control panel error codes
Error 1 (E1)
Power source is not calibrated.
Calibrate power source.
Error 2 (E2)
Undervoltage
Check the mains network connection and fuses.
Error 3 (E3)
Overvoltage
Check the mains network connection and fuses.
Error 4 (E4)
Overheating. Also the overheating pilot lamp
is on. Machine drops welding current for 30s. If
error conditions still apply:
Machine stops welding (model A)
Machine shuts down (model R).
Ensure free air flow. Let the machine cool down.
Error 5 (E5)
---
Error 6 (E6)
---
Error 7 (E7)
NTC warning. (IGBT overheating). Machine
drops welding current.
Ensure free air flow. Let the machine cool down. Check
the environment temperature.
Error 8 (E8)
NTC error. (IGBT overheating). If error
conditions (Err7) still apply:
Machine stops welding (model A)
Machine shuts down (model R).
Ensure free air flow. Let the machine cool down. Check
the environment temperature.
Error 9 (E9)
Mains network phase alarm.
Check the mains network connection and fuses. If
connected to generator check setup jumper Gen.
Error 10 (E10)
---
Error 11 (E11)
VRD error.
Error 12 (E12)
Power source is locked. Too long short circuit.
Machine stops welding (model A)
Machine shuts down (model R).
Avoid long short circuits (20s).
Error 13 (E13)
Wrong panel type (R-type control panel
connected to A-type HiArc or vice versa).
R-type HiArc accepts only R-type (regular) control
panel.
Error 14 (E14)
Current feedback is missing.
Contact Kemppi service representative.
6.
Ordering COdes
HiArc S 400R
63114002
HiArc S 400A
63114001
HiArc S 400A
cellulose kit included
6311400101
Welding cable
50 mm², 5 m
6184501H
70 mm², 5 m
6184701H
Earth return cable
50 mm², 5 m
6184511H
70 mm², 5 m
6184711H
Display cover
SP006989
Slide bars
SP007023
R10H remote control for HiArc S 400A
6185431H
TTM 15 V BC
4 m
627143201