Kemppi FastMig MR 200 Operating Manual Download Page 8

EN

2.3  MR 200 and MR 300 operations

ON/OFF (1)

The wire feed unit remains in the OFF position when the power source is switched on, thus 

preventing start-up. ’OFF’ is shown on the display.
When the ON/OFF button is pressed for more than 1 second, the unit starts up. The unit is now 

ready for welding and will automatically return back to its previous position, before the power 

was cut off. The wire feed unit starts up also by pressing three (short) times the switch of the 

welding gun.

Basic settings and displays

The wire feed speed is set via left potentiometer (control knob) and the value is shown on the 

left display. The welding voltage is set via right potentiometer (control knob) and the value is 

shown on the right display.
During welding, the left display shows the actual welding current value and the display on the 

right shows the welding voltage.
With electrode welding (MMA) the welding current value is set via the potentiometer and 

the value is shown on the left display. The display on the right shows the idling voltage of the 

power source. During welding the left display shows the actual welding current value and the 

display on the right shows the welding voltage.
When the MIG dynamics adjustment is activated with Arc Force/Dynamics button the Mig 

dynamics value is adjusted via right potentiometer (control knob) (see the information on 

adjustment of MIG dynamics).

Adjustment of MIG dynamics/Arc Force (3)

With MIG welding dynamics adjustment is influenced on welding stability and spatter 

amount. Zero setting is recommended basic setting. Values –> min (-9 ... -1), softer arc for 

reduced spatter amount. Values –> max (1 – 9), harder arc for increased stability and when 100 

% CO₂ shielding gas is used when welding steel.
With electrode welding Arc Force adjustment is influenced on welding stability. Adjustment 

is needed for using different types of electrodes. Control range (-9 ... 0) is commonly used for 

welding electrodes for stainless steel. Control range (0 – 9) is used for harder arc characteristic 

to increase stability, e.g. for welding with thicker basic electrodes and using lower current 

value  than recommendated. Factory set value (0) is a good general use for adjusting the 

roughness of the arc.

Selection of air/liquid-cooled MIG gun (4)

Selection of air-cooled/liquid-cooled MIG gun is activated by pressing buttons 3 and 5 

simultaneously (for more than 1 second). When ‘Gas’ is shown on the display, the welding 

equipment will assume that an air-cooled MIG gun has been connected. If the above buttons 

are pressed again, the text ’CooLEr’ appears on the display and the LED indicating liquid 

cooling selection lights up. In this case, the welding equipment will assume that a liquid-

cooled MIG gun has been connected to the equipment. When liquid cooling is selected, the 

liquid cooling unit will start up in connection with the next equipment start-up.
The selection can also be made through the SETUP function.

FastMig MR 200, MR 300

6

Summary of Contents for FastMig MR 200

Page 1: ...al Bruksanvisning Gebrauchsanweisung Manual de instrucciones K ytt ohje Manuel d utilisation Manuale d uso Gebruiksaanwijzing Brugsanvisning Instrukcja obs ugi Manual de utiliza o Bruksanvisning EN DA...

Page 2: ......

Page 3: ...OPERATING MANUAL English...

Page 4: ...1 Connecting and mounting the panels 4 2 2 Functions of MR 200 and MR 300 panel 5 2 3 MR 200 and MR 300 operations 6 2 4 Panel MR 200 and MR 300 Setup parameters 8 3 FastMig error codes 10 4 Disposal...

Page 5: ...products contact Kemppi Oy consult an authorised Kemppi dealer or visit the Kemppi web site at www kemppi com The specifications presented in this manual are subject to change without prior notice Imp...

Page 6: ...bottom edge of the panel behind the securing clips on the machine Remove the fixing pin from the top edge with for example a screwdriver Then gently push the upper part of the panel into place Make su...

Page 7: ...y b Adjustable parameters display 7 Selection of MIG MMA process 8 a Selection of switching logic 2T 4T b Long press Setting the basic parameters SETUP 9 a Adjustment of wire feed speed b Adjustment o...

Page 8: ...of MIG dynamics Adjustment of MIG dynamics Arc Force 3 With MIG welding dynamics adjustment is influenced on welding stability and spatter amount Zero setting is recommended basic setting Values min...

Page 9: ...oltage Selection of MIG operating procedure 8 Gun trigger logic selection Short Press 2T 4T selection Long Press Setup functions Setup 8 When the adjustment of SETUP parameters has been confirmed with...

Page 10: ...dd 3 or 6 3 Wire feeder bus address Using features of PMT Gun Gun OFF on on on PMT gun OFF other gun Gas Guard Connected GG no YES on Implementation of gas guard LongSystem Mode LSY OFF on OFF on Give...

Page 11: ...f start pulse Device Address Add 3 or 6 3 Wire feeder bus address Code Entry Cod Ent Entering license codes manually 1 Adjust right potentiometer to Ent 2 Press REMOTE 3 Set code with right potentiome...

Page 12: ...Check the extension lead and connections Err 55 Power source is busy The communication channel is busy The power source is being used by another wire feed unit or the programming for some other device...

Page 13: ...es as follows 1 Press any button on either control panel except the ESC button Add Device Address is displayed 2 Change the device address using the right hand control knob 3 Return to normal status b...

Page 14: ...28 LANGG NS DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info pl ke...