2.4  Panel MR 200 and MR 300 Setup parameters

Normal MIG welding Setup -parameters

Name of 

parameter

Name on 

display

Parameter 

values

Factory 

setting

Description

Pre Gas Time

PrG

0.0 – 9.9 s

0,0 s

Pre gas time in seconds

Post Gas Time

PoG

0.0 – 9.9 s

Aut

Post gas time in seconds or automatically according to 
welding current (Aut)

Creep Start Level

CrE

10 – 170%

50 %

Percentage of wire feed speed: 
10 % slowed start 
100 % = no creep start function
170 % accelerated start

Start Power

StA

-9 ... +9

0

Strength of start pulse

Post Current Time

PoC

-9 ... +9

0

Post current

Arc Voltage

Ard

OFF, on

OFF

on: Display shows arc voltage 
OFF: Display shows pole voltage

Cable Length

CAb

std, 5 – 80m std

Cable loss is calculated for optimal arc control and for the 
Arc Voltage display

Common Setup -parameters for MIG processes

Name of 

parameter

Name on 

display

Parameter 

values

Factory 

setting

Description

Device Address

Add

3 or 6

3

Wire feeder bus address

Using features of 

PMT Gun

Gun

OFF, on

on

on = PMT gun
OFF =  other gun

Gas Guard 

Connected

GG

no, YES

on

Implementation of gas guard

LongSystem Mode

LSY

OFF, on

OFF

on: Gives optimum welding characteristics with long 
welding cables

Code Entry

Cod

---, Ent

---

Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)

Water Cooler

Coo

OFF, on

on

Enables water cooler

Wire Inch Stop

Inc

OFF, on

on

OFF = Stops wire inch in case arc does not ignite
on = Feeds wire as long as the welding gun start switch 
is pressed.

Auto Wire Inch

AIn

OFF, on

on

SuperSnake Automatic Wire Inch function. Wire Inch 
button runs the filler wire from the wire feeder up to the 
SuperSnake.

Demo Licence Time

dEt

3-h, 2-h, **’, 
**’’, OFF

The remaining time for the WiseDemo licence  
(readable value only).
3-h = max. 3 hours left
2-h = max. 2 hours left
**’ = ** minutes left
**’’ = ** seconds left
OFF = Demo period has expired.

FastMig MR 200, MR 300

8

Summary of Contents for FastMig MR 200

Page 1: ...al Bruksanvisning Gebrauchsanweisung Manual de instrucciones K ytt ohje Manuel d utilisation Manuale d uso Gebruiksaanwijzing Brugsanvisning Instrukcja obs ugi Manual de utiliza o Bruksanvisning EN DA...

Page 2: ......

Page 3: ...OPERATING MANUAL English...

Page 4: ...1 Connecting and mounting the panels 4 2 2 Functions of MR 200 and MR 300 panel 5 2 3 MR 200 and MR 300 operations 6 2 4 Panel MR 200 and MR 300 Setup parameters 8 3 FastMig error codes 10 4 Disposal...

Page 5: ...products contact Kemppi Oy consult an authorised Kemppi dealer or visit the Kemppi web site at www kemppi com The specifications presented in this manual are subject to change without prior notice Imp...

Page 6: ...bottom edge of the panel behind the securing clips on the machine Remove the fixing pin from the top edge with for example a screwdriver Then gently push the upper part of the panel into place Make su...

Page 7: ...y b Adjustable parameters display 7 Selection of MIG MMA process 8 a Selection of switching logic 2T 4T b Long press Setting the basic parameters SETUP 9 a Adjustment of wire feed speed b Adjustment o...

Page 8: ...of MIG dynamics Adjustment of MIG dynamics Arc Force 3 With MIG welding dynamics adjustment is influenced on welding stability and spatter amount Zero setting is recommended basic setting Values min...

Page 9: ...oltage Selection of MIG operating procedure 8 Gun trigger logic selection Short Press 2T 4T selection Long Press Setup functions Setup 8 When the adjustment of SETUP parameters has been confirmed with...

Page 10: ...dd 3 or 6 3 Wire feeder bus address Using features of PMT Gun Gun OFF on on on PMT gun OFF other gun Gas Guard Connected GG no YES on Implementation of gas guard LongSystem Mode LSY OFF on OFF on Give...

Page 11: ...f start pulse Device Address Add 3 or 6 3 Wire feeder bus address Code Entry Cod Ent Entering license codes manually 1 Adjust right potentiometer to Ent 2 Press REMOTE 3 Set code with right potentiome...

Page 12: ...Check the extension lead and connections Err 55 Power source is busy The communication channel is busy The power source is being used by another wire feed unit or the programming for some other device...

Page 13: ...es as follows 1 Press any button on either control panel except the ESC button Add Device Address is displayed 2 Change the device address using the right hand control knob 3 Return to normal status b...

Page 14: ...28 LANGG NS DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info pl ke...

Reviews: