EN
3
Installation of frost-proof outer
fitting and spray protection
Insert the frost-proof outer fitting (3) into the hole and attach using the
two M6 screws (4) provided.
Connect the outer fitting (3) to the water supply
(copper pipe Ø 15 mm or AG R ½“)
Insert the spray protection plate (8) with the central hole (Ø 35 mm)
below the frost-proof outer fitting, and connect to the attachment points
provided on the rear wall using the M6 screws provided (9).
Warning!
Installation must be carried out by qualified plumbers!
Note!
The valve seat (thread R ½“) must be located in
the frostfree area.
Note!
The masonry must be at least 180 mm thick (see frost-free area).
4
Conduct functional testing of the frost-proof outer fitting (3).
Note!
Due to the automatic draining of the frost-proof outer fitting (3)
after removal of water, water will continue to drain out for a few
seconds after closing the fitting (frost safety). For this reason, the
fitting only needs to be closed gently.
Note!
To ensure the correct ‘frost safety‘ function, hoses and other
attachements must be removed before the start of the frost
period!
Functional testing
1.
1.
2.
3.