- 71 -
7.3
Troubleshooting
Fault
Possible cause
Note
Green illuminated
ring around the
on/off switch does
not light up.
No power supply
available
Have the power supply
checked by a qualified
electrician
Product does not
start
No power supply
available
Have the power supply
checked by a qualified
electrician
Yellow signal lamp
flashes at regular
intervals
Product maintenance is
due
Contact manufacturer's
service department
Yellow signal lamp
flashes briefly twice
in a row at regular
intervals
Motor protection has
tripped
Let the product cool down,
change the cooling air
intake filter
Yellow signal lamp
flashes briefly twice
in a row at regular
intervals
Rotary field error
Have the rotary field
checked by a qualified
electrician
Yellow signal lamp
flashes briefly 4x at
regular intervals
Compressed air error
Check compressed air
supply
Yellow signal lamp
flashes briefly five
times at regular
intervals
Dust collection cartridge
full or not inserted
correctly
Change dust collection
cartridge or check for
correct fit
Signal horn sounds The set minimum
extraction rate has not
been reached. Filter
inserts saturated,
piping/extraction
system closed off
Filter change required,
check piping/extraction
system, contact service
Requirements are no
longer met!
Dust particles
escape on the clean
air side
Filter insert damaged
Change filter insert
Contact the
manufacturer’s service
department
Tab. 17: Troubleshooting