EN
1502762-02
- 58 -
Item Description
Note
1
Device button with power light
Switches the product on
or off
2
Signal light
Signals the operation of
the product
3
Built in regulator for run-on time in
start-stop operation
4
Maintenance socket
For service personnel
only
5
Pressure measurement opening
For service personnel
only
6
Signal horn
7
Connector socket for start-stop sensor
8
Pressure switch
For service personnel
only
Tab. 13: Operating elements
•
I/0 switch (item 1)
The product is switched on and off by pressing the switch.
The green signal lamp of the switch indicates trouble-free operation of
the product or the readiness for operation when using an optional
start/stop sensor.
•
Signal lamp (item 2)
The yellow signal lamp indicates a fault or an error in the product. These
faults are displayed using different blink codes for optical reference.
•
Signal lamp flashes evenly at regular intervals:
Product maintenance is due, inform service
•
Signal lamp flashes briefly twice in a row at regular intervals:
The motor protection switch has triggered, inform service
•
Signal lamp flashes briefly three times in a row at regular
intervals:
Incorrect rotating field, the fan is rotating in the wrong
direction. To remedy this, an electrician swaps two phases in
the CEE connector plug.
Summary of Contents for MaxiFil 65 650
Page 2: ...Typenschild einkleben ...
Page 106: ...FR 1502762 02 106 7 3 dépannage ...
Page 132: ...NL 1502762 02 132 ...
Page 368: ...РУ 1502762 02 368 7 3 Устранение неисправностей ...
Page 421: ...SL 1502762 02 421 ...
Page 449: ......