Precautions 

for installation, maintenance and operation

Use  

The KEMPER FROSTI

®

 is used as a 

frost-proof outdoor tap.  

Do not use the product for other  

purposes than described above. 

Any other uses constitute misuse.

Warnings

Be sure to read and follow the warn-

ings in the manual. Failing to do so 

can lead to personal injury or material 

damage!

Important warnings:

Warning! 

Highlights risks 

that may result in injury, ma-

terial damage or contamination 

of drinking water.

Note! 

Highlights risks that 

may result in damage to the 

plant or dysfunction.

 

Important advice to the operator

Medium: water

maximum operating temperature 90 °C, 

pressure rating PN 16  

1. The valve should only be used

  - in good order and condition

  - as intended

2. 

During periods prone to frost,    

  always separate the hose and    

  all screw connections from  

 

  the tap.

Maintenance

In accordance with DIN EN 806-5, 

maintenance is to be carried out on the 

tap annually.

Be sure to comply with the local  

regulations on waste recycling  

and disposal.

Installation and operation 

Read the manual and follow the  

instructions before installation. 

Installation and maintenance must be 

carried out by qualified plumbers. 

 Provide manual to the plant operator 

and keep on hand for further reference!

The place of installation may not be at 

risk of flooding.

Do not combine components of Figure 577 

with parts from earlier versions.

Perform a leak test after installation 

and before commissioning!

Priority must be given to the national 

standards and provisions on sanitary 

installations and accident prevention. 

All dimension specifications are given  

in mm.

Warranty 

 

Warranty or liability are voided through:

- Disregard of installation instructions.

- Damage due to faulty installation.

- Unauthorised product modification.

- other incorrect operation.

Summary of Contents for FROSTI XS

Page 1: ...anleitung Frostsichere Außenarmatur FROSTI XS Fig 577 90 EN Installation and Operating Manual Frost proof outdoor tap FROSTI XS Fig 577 90 NL Installatie en bedieningshandleiding Vorstbestendige buitenkraan FROSTI XS Fig 577 90 ...

Page 2: ...stand bestimmungsgemäß 2 In Frostperioden unbedingt Schlauch und alle Verschraubungen von der Armatur trennen Wartung Nach DIN EN 806 5 ist an der Armatur einmal jährlich eine Wartung vorzunehmen Die örtlichen Vorschriften zur Abfall verwertung bzw beseitigung sind zu beachten Montage und Gebrauch Anleitung vor Montagebeginn oder Ge brauch sorgfältig lesen und den Anwei sungen folgen Montage und W...

Page 3: ...separate the hose and all screw connections from the tap Maintenance In accordance with DIN EN 806 5 maintenance is to be carried out on the tap annually Be sure to comply with the local regulations on waste recycling and disposal Installation and operation Read the manual and follow the instructions before installation Installation and maintenance must be carried out by qualified plumbers Provide...

Page 4: ...n in de hand leiding in acht en volg ze op Het niet in acht nemen van de waarschuwingen kan tot letsel of materiële schade leiden Markering belangrijke waarschuwingen Waarschuwing Markeert gevaren die tot letsel materiële schade of verontreiniging van het drinkwa ter kunnen leiden Aanwijzing Markeert gevaren die tot schade aan de installatie of tot storingen tijdens het functi oneren kunnen leiden...

Page 5: ...r leichtes Zudrehen erforderlich 10 Sekunden Wasserablauf sind in Ordnung EN Turn only lightly to close 10 seconds water expiration is all right NL Slechts licht afsluiten het water kan nog 10 seconde doorlopen FR Fermer la robinet sans effort l eau coule encore pendant 10 secondes CS Stačí jen lehké oto čení po 10 vte řina odtoku vody v po řádku i i Pos Art No DN 15 1 E21055730000100 2 L110059000...

Page 6: ...6 16 K410057790001 00 10 2019 www kemper olpe de i a b ...

Page 7: ...waarde wordt voldaan DE Hinweis Der Ventilsitz muss an der Innenseite der Wand bzw so nah wie möglich an der Innenwand im frostgeschützten Bereich ohne Einsatz von Dämmmaterial platziert werden um das Risiko von Frostschäden zu verringern Keine Gewährleistung oder Haftung bei Nichtbeachten dieses Hinweises EN Note To avoid frost damage the valve seat must be installed as near as possible to the in...

Page 8: ...order to prevent stagnation and bacterial contamination in the supply it is recommended to loop the tap in the drinking water system For technical and hygienic reasons it is necessary to execute the last min 100 mm and max 10 x DN as a functional individual supply line The tap must be installed at least 250 mm above the maximum Fluid level NL Waterleidinginstallatie Om stagnatie en vervuiling in d...

Page 9: ...9 16 K410057790001 00 10 2019 www kemper olpe de 1 2 1 2 ...

Page 10: ...10 16 K410057790001 00 10 2019 www kemper olpe de 2x 2x 4 3 1 2 1 3 2 ...

Page 11: ...11 16 K410057790001 00 10 2019 www kemper olpe de 3 2x 5 2 1 ...

Page 12: ...12 16 K410057790001 00 10 2019 www kemper olpe de 0 C 0 C pag 8 100 DN 6 2 1 ...

Page 13: ...13 16 K410057790001 00 10 2019 www kemper olpe de 8 7 1 2 3 ...

Page 14: ...14 16 K410057790001 00 10 2019 www kemper olpe de FROSTI č če ní ř řádk u i 4 2 9 3 5 6 1 ...

Page 15: ...15 16 K410057790001 00 10 2019 www kemper olpe de Fig 5740100100 Fig 5750000300 Fig 640 50 ...

Page 16: ...K410057790001 00 10 2019 Service Hotline 49 2761 891 800 www kemper olpe de info kemper olpe de i i Gebr Kemper GmbH Co KG Harkortstraße 5 D 57462 Olpe ...

Reviews: