![Kemper 82755 Operating Manual Download Page 88](http://html.mh-extra.com/html/kemper/82755/82755_operating-manual_663127088.webp)
EN
1502965-01
- 88 -
NOTE
Products with IFA certification according to requirements for W3/IFA
certified welding fume separation class. (See "Technical data" chapter)
The IFA approval becomes void if:
•
The product is used other than as intended or is subject to
constructive modifications.
•
Non-original spare parts, in accordance with the spare parts list, are
used.
•
Only original replacement filters, because they guarantee the necessary
filter efficiency and are matched to the product and its performance
characteristics.
•
Switch the product off using the on/off switch.
•
Secure the product against unintentional switching on. If available, pull
out the mains plug or secure the main switch in the 0 position with a
padlock.
•
Disconnect the pressure supply, if present, and let the compressed air
present in the product flow out via the condensate drain valve.
7.3.6
Main filter change
Carry out the main filter replacement as follows:
1. Switch off the product using the on/off switch.
2. Disconnect the product from the power supply by unplugging.
3. Disconnect the product from the compressed air supply.
4. Provide a new filter cartridge and the associated disposal bag.