EN
1502965-01
- 85 -
Fig. 32: Draining the condensate
Pos. Description
Pos. Description
1
Condensate drain valve
2
Container
Tab. 25: Positions on the product
To drain the condensate, please proceed as follows:
1. Hold a container (Pos. 2) under the outlet opening of the condensate
drain valve (Pos. 1).
2. With the other hand, slowly open the condensate drain valve (Pos. 1) at
the knurled screw.
3. Only close the condensate valve (Pos. 1) again when just air is escaping.
7.3.3
Checking the compressed air container with
compressed air safety valve
NOTE
The product has one or more compressed air containers with
compressed air safety valve.
Products with compressed air container and safety valve must be
serviced/checked according to current national regulations.