13
Owner’s manual
EN
TROUBLESHOOTING
Low sensitivity of detection or the floodlight does not work:
• Check if there are any obstacles in front of the device.
•
Check if the detection range is not exceeded.
• Check if the device is mounted at an appropriate height.
• Check if the brightness settings are consistent with the ambient
light.
• When the environment temperature is similar to human body
temperature then detection sensitivity may slightly decrease.
The light does not turn off:
• Check if there is constant motion within the detection range.
• Check if the time is not set to the maximum (10 minutes).
SPECIFICATION
URZ3476
URZ3477
Light source
15 pcs SMD2835
28 pcs SMD2835
Power
10 W
20 W
Color temperature
4000 K
Luminous flux
800 lm
1600 lm
Efficiency
80 lm/W
Power factor
>0,5
Beam angle
120°
Detection angle
120º
Detection distance
up to 12 m
CRI
>70
Protection class
I
Protection rating
IP65
Working temperature
-30°C ~ +50°C