"Edit". A new program may be placed in front or added here in the window that opens then or a marked program may be deleted.

"Configuration" is usually set automatically. Another LPT printer port, if available, may be chosen manually. In addition  the access

time to the LPT1 port can be adjusted. If your computer cannot cope with the automatically set time (crashes, etc.), you should try

other times. If your computer does not attend the LPT1 port evenly (the signal arrives with interruptions and the motors start sput-

tering), you should try another adjustment.

"Exit" to end the program.

Control of the laser motors via the keyboard:

1.

Call the program (click the icon).

2.

Click the button "Output OFF".

3.

Switch on the power supply of the laser board.

4.

Click the knob "Motor 1" with the cursor and move the cursor up or down while pressing the mouse key. Cast loose the

mouse key at the desired value (e.g. display - 42). While doing so the knob on the screen turns and the setting value will be

shown in the window below.

5.

Proceed in the same manner with motor 2 and motor 3. Example: Adjust motor 2 to 60 and motor 3 to 65.

6.

Click the button "Output On" now (switch on). The motors rotate now and the laser is switched on.

7.

Now you may change the adjustments as you like by clicking the knobs for the motors again and move the cursor up or

down while pressing it. Motor 1 and Motor 2 can be adjusted in 2 senses of rotation, motor 3 can only be adjusted into one

direction.

8.

Please adjust the laser turnoff function: Set motor no. 3 to "30". Then adjust the trimming potentiometer "P1" on the laser

board in such a manner that the laser just turns on. If you continue now to adjust motor 3 downward, the laser must stop

and the laser must switch on again when adjusting the motor upward. This is for safety: When all motors stand still, the la-

ser must be off. A stationary laser point may damage the eyes.

How to program program flows:

1.

Adjust the first desired setting as mentioned under points 1…5 of the description "control via the keyboard". Then adjust

the time, i.e. how long this setting shall run. There is a window “minutes” and “seconds” in the top right-hand corner of the

screen. Place the cursor here, press "Backspace" on the keyboard and adjust e.g. 5 seconds.

2.

Now click "Save Step" to save this setting.

3.

An additional programming line may be added by clicking the button “Add Step".

4.

Here choose for example the settings Motor 1: "30", Motor 2: "0", Motor 3: “50” time: 4 seconds.

5.

Now press "Save Step" again to save this programming line.

6.

Now many other program lines may be added with "Add Step" and "Save Step" as described above.

7.

As soon as you will have finished your desired programming, you may save it under any name.

8.

To save press: "File" and then "Save As" and enter the name of the program: delete the name that is shown there with

"Backspace" and enter your own name. Then press “Save”.

Start a program:

You may either get the program from the memory by: "File" then "Open", click the desired program and confirm with „öffnen“ or

start the new program that was just written with "Start". The program runs once after that while the red point in the program line

indicates which program line is just running. Following the run of the last program line, the program stops automatically.

Start a program with "Infinite Loop"

You may also start a program in such a manner that it starts automatically over and over again as soon as it has run through. At

first press "Repeat" and then "Start".

The running program may be interrupted any time with "Pause" and restarted again or truncated with "Stop".

Please observe during programming that the motors have a natural inertia and cannot reach the adjusted speed immediately. If

you have any difficulties with the program on your computer (crashes, operation gets too slow), this is due to the insufficient run

time how your computer attends the LPT1 port. In this case please adjust a longer run time under  "Configuration" and "Periodic

Interrupt". The shorter the time the better the motors run (but for this purpose the computer must be quick). The longer the time,

the better the program runs on slow computers (> 250 MHz). But the motors interrupt the run for a short time.

——————————————————————————————————————————–

FIN / B240 PC-ohjatun "Laser-Show" ohjelmiston lyhyt selostus:

Käyttöliittymän selostus:

"Index" Tämä ikkuna osoittaa, mitä ohjelmarivejä käynnissä olevassa ohjelmassa juuri käsitellään.

"Motor 1...3" näillä 3 nupilla voidaan peilimoottoreiden kiertosuunta tai kierrosluku asettaa. Säätimien alapuolella olevassa

ikkunassa osoitetaan teholuku, jolla moottori kiertää sillä hetkellä. Käyttö: Siirrä hiiri kyseiseen kiertosäätimeen, napsauta ja

liikuta hiiren kohdistinta ylös tai alas, kunnes haluttu arvo on asetettu. Pidä hiiren painike painettuna säädön aikana.

Summary of Contents for Laser Show B240

Page 1: ...n den Installationsvorgang beginnen durch das bestätigen mit der Taste Ok Beim Start des Installationsvorganges wird ein Fenster geöffnet in dem die Installation angekündigt wird This will install Kemo Electronic Laser Show Do you wish to continue Drücken Sie Nein wird die Installation abgebrochen drücken Sie Ja erscheint ein neues Begrüßungs Fenster Betätigen Sie die Taste Next wird Ihnen ein Ord...

Page 2: ...nêtre pour la configuration du Laser Show apparaît qui ne va pas apparaître plus au premier appel Vous pouvez accepter les entrées par appuyer sur la touche Ok Ensuite vous arrivez au programme Laser Show F Instrucciones para el montaje Montar la placa según los dibujos la lista de piezas y las Instrucciones generales para kits M1003 folleto incluido El largo del cable hacia el ordenador debe ser ...

Page 3: ...rding to the drawings parts list and the General Instructions for Kits M1003 attached leaf let The cable towards the computer may have a maximal length of 2 m Please use a stabilized 12 V power supply as operating voltage which has a performance of at least 400 mA The motors must be stuck on a base at a certain angle to each other For this purpose we printed a position drawing 1 1 in this descript...

Page 4: ...re laser aansluiten wil dan moet dit via een eigen voeding Aan de laser uitgang van de print monteerd u een relais of optorelais 3 V 50 mA en stuur hiermee de grote laser aan Toelichting zo lang spiegelmotor no 3 goed draait kan de laser geen vaste punt projecteren Voor het oog is een vaste punt het gevaarlijkst Toepassings mogelijkheden Met deze schakeling kunt u verschillende laserfiguren op de ...

Page 5: ...e e pulsar a tecla Abrir öffnen Agora a linha de instrução indica A setup exe ou B setup exe e pode começar o processo de instalação através confirmar com a tecla Ok Ao começar um processo de instalação é aberta uma janela onde está indicada a instalação This will install Kemo Electronic Laser Show Do you wish be continue Ao pulsar No Nein é a instalação interrumpida ao pulsar Yes Ja aparece uma n...

Page 6: ...http www kemo electronic de Kemo Germany 14 000 B240 V012 Optocoupler TCDF1900 TCDF1910 ION 200 mA ...

Page 7: ...http www kemo electronic de Kemo Germany 14 000 B240 V012 25 13 14 1 3 V 3 V 12 V 0 4 A Abschirmung des Kabels Shielding of the cable Originalgröße M3 M2 M1 ...

Page 8: ... wird nicht mitgeliefert D2 Laser not enclosed Spiegel mirror D1 R5 R10 R4 P1 R9 R1 IC1 IC2 IC3 IC4 IC5 R2 R3 R11 R8 R7 R15 R6 IC6 C R13 R14 R16 R17 R12 R18 R19 http www kemo electronic de Kemo Germany 14 000 B240 V012 ...

Page 9: ...r kann ein neues Programm im dann aufklappenden Fenster davor oder dazugesetzt werden oder ein markiertes Pro gramm gelöscht werden Configuration stellt sich normal automatisch ein Man kann manuel einen anderen LPT Druckerport anwählen falls vorhanden Außerdem läßt sich die Zugriffszeit zum LPT1 Port einstellen Falls Ihr Computer mit der automatisch eingestellten Zeit nicht zu rechtkommt abstürzt ...

Page 10: ...natürliche Massenträgheit haben und nicht sofort die einge stellte Geschwindigkeit erreichen können Wenn Sie Schwierigkeiten mit dem Programm auf Ihrem Computer haben stürzt ab Bedienung wird zu langsam dann liegt das an der mangelnden Laufzeit wie Ihr Computer den LPT1 Port bedient In diesem Fall stellen Sie bitte eine längere Laufzeit unter Configuration und Periodic Interrupt ein Je kürzer die ...

Page 11: ...be estar conectado Un punto láser puede perjudicar los ojos Programar los desarrollos del programa 1 Ajustar la primera regulación deseada como descrito bajo los puntos 1 5 de la descripción Mando por el teclado Después ajustar el tiempo es decir cuanto tiempo este ajuste debe correr Sobre la pantalla arriba por la derecha se encuentra una ventanilla con minutos y segundos Poner el cursor aquí pul...

Page 12: ...devant ou de plus dans la fenêtre que s ouvre d après ou effacer un programme marqué Configuration est normalement ajusté automatiquement On peut choisir manuellement un autre port d imprimante si disponible En outre il est possible de régler le temps d accès vers le port LPT1 Si vous ordinateur ne se débrouille pas avec le temps ajusté se plante etc vous devriez essayer d autres temps Si votre or...

Page 13: ...tesse réglée tout de suite Si vous avez des difficultés avec le programme sur votre ordinateur se plante le maniement devient trop lent ceci est dû à la durée d exécution insuffisante comme votre ordinateur dessert le port LPT1 En ce cas veuillez ajuster une durée d exécution plus longue sous Configuration et Periodic Interrupt Plus court le temps plus mieux les moteurs marchent mais pour cela il ...

Page 14: ...ve Step to save this setting 3 An additional programming line may be added by clicking the button Add Step 4 Here choose for example the settings Motor 1 30 Motor 2 0 Motor 3 50 time 4 seconds 5 Now press Save Step again to save this programming line 6 Now many other program lines may be added with Add Step and Save Step as described above 7 As soon as you will have finished your desired programmi...

Page 15: ...sim osoituksessa 42 Tällöin kiertonuppi kiertyy kuvaruudussa ja alapuolella olevassa ikkunassa osoitetaan asetettu arvo 5 Tee sama toimenpide myös moottorilla 2 ja moottorilla 3 Esimerkki Moottorin 2 asetat arvoon 60 ja moottorin 3 arvoon 65 6 Napsauta nyt painiketta Output On käynnistys Nyt moottorit pyörivät ja laser on kytkettynä 7 Nyt voit muuttaa asetuksia mielivaltaisesti napsauttamalla taas...

Page 16: ...ns dit regelen de muis toets ingedrukt houden Min Sec in dit venster kan ingesteld worden hoe lang de instelling een regel tijdens het programma loopt nog verder moet gaan Save Step Door het aan klikken van deze knop wordt een programma stap vast gezet in het geheugen 1 instelling met 3 moto ren en ingestelde tijd Output On met deze knop worden de motoren in of uitgeschakeld sturing naar poort LPT...

Page 17: ...mma in Met backspace de naam en speichern is voor het wissen zodat u een nieuwe naam kunt inbrengen Starten van het programma Of u haalt het programma uit het geheugen met File daarna Open aan klikken en met öffnen onderstrepen of u start het net nieuw geschreven programma met Start Het programma loopt helemaal door waarbij de rode punt in de programma aangeeft welk programma nu loopt Aan het eind...

Page 18: ...8 Ajustar a função do desconectar do laser Ajustar o motor Nr 3 a 30 Depois regular o potenciómetro de ajuste P1 sobre a placa do laser de maneira que o laser justamente ligue Se agora reduzir o motor 3 deve o motor desligar o laser deve ligar novamente quando regular o motor a um nível mais elevado Isto serve como segurança Se todos os motores estiverem parados o laser deve estar desligado Um las...

Page 19: ...a isso deve o computador ser rápido Quanto mais longo é o tempo melhor corre o programa tambem em computadores lentos 250 MHz Os motores interrumpem a marcha por curto tempo RUS B240 Beschreibung der Bedienungsoberfläche Index Motor 1 3 Min Sec Save Step 1 Output On LPT1 Insert Step Add Step Save Step Delete Step File Save Start Pause Stop File New Open S v Save as Edit Configuration LPT1 LPT1 Exi...

Page 20: ... 2 3 8 3 30 1 3 3 1 1 5 Backspace 5 2 Save Step 3 Add Step 4 1 30 2 0 3 50 4 5 Save Step 6 Add Step Save Step 7 8 File Save As Bac s ace Speichern File öffnen Start Repeat Start Pause Stop LPT 1 Configuration Periodic Interrupt 250 M ...