background image

ver.5

20/08/2020

22

Summary of Contents for CELESTIAL 900 WITH FAN

Page 1: ...ETION 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty Other parts are covered by a one year limited warranty Head Office 13 French Avenue Brendale Queensland 4500 Telephone PH 07 3490 5500 Facsimile FAX 07 3490 5520 Website www jetmaster com au Business hours Monday to Thursday 7 30am 4 00pm Friday 7 30am 2 00pm Email sales jetmaster com au 20 08 2020 ver 5 1 ...

Page 2: ...WITH FAN AND HEAT DUCTING BOX FOR MASONRY HEBEL B H I D H DIMENSIONS DESC MODEL A B C D E F G H I J K L M CELESTIAL 900 WALL INSERT 468 495 608 1054 252 610 202 528 1180 672 776 268 L M ver 5 J K FASCIA 960 442 20 08 2020 2 ...

Page 3: ...T B A A UNIT HEIGHT ABOVE FLOOR 200 300 400 500 600 700 B HEARTH DIMENSION FORWARD OF UNIT 725 715 665 594 492 335 ver 5 UNDERNEATH UNIT AND HEARTH THICKNESS MUST BE A MINIMUM 18mm NON COMBUSTIBLE MATERIAL FC SHEET OR SIMILAR 20 08 2020 3 ...

Page 4: ... UNIT X Y NOTE IF Y IS LESS THAN 200mm THEN REFER TO HEARTH MEASUREMENT ON PREVIOUS PAGE X MIN DEPTH MEASUREMENT mm 300 Y MIN HEIGHT INCREASE mm 200 ver 5 UNDERNEATH UNIT AND HEARTH THICKNESS MUST BE A MINIMUM 18mm NON COMBUSTIBLE MATERIAL FC SHEET OR SIMILAR 20 08 2020 4 ...

Page 5: ...CK 222 4 BAFFLE PLATE SIDE OF 222 MM SHOULD EXTEND FROM SIDE TO SIDE 6 SLIDE THE BAFFLE PLATES ATOP THE OTHER 2 BAFFLE PLATES INTO THE MIDDLE POSITION AS SHOWN LEAVE GAP OF 1 2 MM IN BETWEEN PLATES THE GAPS SHOULD BE ROUGHLY IN THE MIDDLE OF THE AIR TUBES UNIT IS NOW READY FOR USE 5 RE PLACE MIDDLE AIR TUBE BACK INTO POSITION NB MAKE SURE OPEN END OF AIR TUBE IS PLACED INTO REAR OPENING CLOSED END...

Page 6: ...inless steel flue pipe All flue pipes must be connected with pop rivets supplied by installer Rear of unit to Hebel Block 25mm min Hebel Block min thickness 75mm 25mm min clearance between 10 flue and framing 6 Flue Inlet air vents into chase Outlet air vents from chase DETAIL A All 8 10 assembled flues must have the crimps pointing upwards crimped plain All 6 assembled flues must have the crimps ...

Page 7: ...0mm min Below ceiling Triple skin flue system 10 8 and 6 Flue system to be installed to suit AS NZS 2918 2001 25mm min clearance between 10 flue and ceiling framing Inlet air vent 240 x 90 6 Flue Outlet air vent 240 x 90 Located on the front or side of the chase 55mm air gap 9mm Fibre cement sheet Register plate with vented 8 and 10 upstands 600mm min below ceiling CELESTIAL 900 MASONRY BLOCK CONS...

Page 8: ...ver 5 1165 650 NOTE THE APPLIANCE WILL NEED 505mm DEEP OPENING TO THE BACK OF CHASE CELESTIAL 900 MASONRY OPENING CUT SIZE 20 08 2020 8 ...

Page 9: ... ONLY NEEDS TO BE NON COMBUSTIBLE TO CEILING NOTE SIDES AND BACK CAN BE COMBUSTIBLE 9mm FIBRE CEMENT 13mm FYRECHECK OR SIMILAR PRODUCT FRONT FACE NEEDS TO BE ALL NON COMBUSTIBLE MATERIAL STEEL TRACK 25mm PYROTEK BOARD ASSEMBLY TOP VIEW FRONT VIEW TIMBER FRAME 15mm CLEARANCE FROM ZERO CLEARANCE BOX COMBUSTIBLE MATERIAL 25mm CLEARANCE FROM OUTER FLUE TO COMBUSTIBLE MATERIAL 20 08 2020 9 ...

Page 10: ...ver 5 A B J H I C D E F G L K A B C D E F G H I J K L CELESTIAL 900 WITH FAN 933 1254 523 626 626 1073 215 623 95 295 228 304 DIMENSIONS FOR WHITE BOARD ZERO CLEARANCE BOX 20 08 2020 10 ...

Page 11: ...FASCIA TO SLIDE BETWEEN THE BOX AND THE WASHER 3 BEND THE SILICONE TABS INTO POSITION THIS TAB SHOULD BE PARALLEL TO THE FRONT OF THE FASCIA WHEN IN THE CORRECT POSITION 4 SLIDE FASCIA INTO THE REQUIRED POSITION THEN HAND TIGHTEN THE SCREWS AS REQUIRED OR USE AN APPROPRIATE ALLEN KEY OR PLIERS USE A TOUCH UP PAINT ON THE SCREW HEADS AS REQUIRED 5 RE INSTALL THE DOOR BACK ON USE THE REVERSE METHOD ...

Page 12: ... THAT THE DOOR WILL LOCK PROPERLY 3 LOOSEN THE 2 BOLTS AS REQUIRED DO NOT UNSCREW THE BOLTS ALL THE WAY OUT 4 PUSH THE PACKER FROM THE BOTTOM EDGE OF THE ADJUSTMENT ANGLE UNTIL FULLY REMOVED ONLY TAKE OUT WHAT IS NECESSARY RE POSITION THE ADJUSTMENT ANGLE AT THE MARKERS AND TIGHTEN NOTE UP TO 4 PACKERS CAN BE REMOVED IF NECESSARY 5 CLOSE THE DOOR AND CHECK IF THE LATCH LOCKS PROPERLY THE ADJUSTMEN...

Page 13: ...T AND TILT UP THE FRONT EDGE OF THE FAN CASSETTE AT THE LAST MOMENT TO RELEASE IT FROM THE APPLIANCE CAVITY 5 PULL FAN CASSETTE AWAY FROM THE APPLIANCE TAKE NOTE OF THE FAN POSITION WHILST STILL IN THE CASSETTE THIS WILL BE IMPORTANT DURING RE INSTALLATION EARTH WIRE CONNECTORS TO FASCIA CONNECTORS TO FAN WIRES 6 USE A FLAT SURFACE AND LAY THE FAN CASSETTE UPSIDE DOWN REMOVE THE 2 SCREWS HOLDING T...

Page 14: ... COMPLY WITH AS NZS 2918 INCREASE FROM 1000 MIN UNTIL CLEAR WITHIN 3000 OF TOP OF FLUE 3000 ANY NEARBY STRUCTURE 3000 MORE THAN 3000 600 MIN 3000 1000 MIN IF CLEAR WITHIN 3000 OF TOP OF FLUE INCREASE AS NECESSARY UNTIL NOTHING WITHIN 3000 OF FLUE TOP 600 MIN 3000 OR LESS ver 5 20 08 2020 15 ...

Page 15: ...ver 5 20 08 2020 16 ...

Page 16: ...mately 10 to 15 minutes until the new pieces are burning well then it may be returned to its desired setting 6 To set the fire for overnight burn two thirds fill the firebox with hardwood and fully open the air inlet Once the fire is burning well the air inlet control should be shut down approximately three quarters of its travel Setting the air inlet control may be varied to suit your particular ...

Page 17: ...ver 5 20 08 2020 18 ...

Page 18: ... with higher heat production than wet or green wood The difference between the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green hardwood Green white ash for instance is not as good a fuel as dry tamarack The reason for the superiority of dry wood is easy to understand Heat cannot be produced until moisture has been d...

Page 19: ... for damaged heater 5 CLAIMS 5 1 I Kemlan will provide a full replacement of the heater in the first five years after installation ii Replacement in the subsequent five years i e sixth to tenth year after installation will be on the following basis Owner will pay fifty percent of the current retail price if the claim is made in the sixth year tenth year after purchase 5 2 Replacement of heater sub...

Page 20: ...ver 5 NOTES 20 08 2020 21 ...

Page 21: ...ver 5 20 08 2020 22 ...

Page 22: ...ver 5 20 08 2020 23 ...

Reviews: