KEMKRAFT
ENGINEERING, INC.
MODEL KEI-200 SPC DIGITAL INCLINOMETER
96-012.doc
Page
2
47650 CLIPPER DR. PLYMOUTH TWP., MICHIGAN 48170 (734) 414-6500
OPERATION PROCEDURE:
•
This unit should be calibrated once a month. Refer to the
Calibration Procedure
of this
manual.
•
The Inclinometer should be fully charged before use. If the unit is used extensively during
the day it should be charged at night.
•
Depress the power switch, located on the front panel, to turn the unit on. The unit should
display as follows:
XX.X
deg
XX
smpls
avg
XX
avgcnt
XX.X
deg
displays the degree angle value up to a max. of +/-12.7 deg.
smpls:
is the sample counter and indicates the amount of samples stored into the units'
memory.
avg:
is the abbreviation for average and will display the average value of the sum of the
samples taken when the SAMPLES button is depressed.
avgct:
is the abbreviation for average counter and will display the amount of averages
stored into the units memory each time the AVERAGE button is depressed.