Operation 

Version: ECO_M_ENG_220303_E001 

 

After pressing the Connect button you should see the following picture 

 

 

Fig 7: directly after connection establishment 

Model code is displayed, if the ECO was purchased together with a sensor, rudimentary sensor information is 

also available (here only ECO without sensor - marked by "??"). 

 

All input fields are outlined in orange and can be changed. "Sensor Serial Number" and "Sensor Model Code" 

should be taken from the calibration protocol or the type plate of the sensor. 

 

 

Fig 8: Selection of the sensor, or entry of the K-factor 

When you select a sensor, the standard measuring range and, via the K-factor, also the measured frequency 

are displayed. These fields can be overwritten manually. 

 

 

Summary of Contents for ECO

Page 1: ...Certified according to DIN EN ISO 9001 Manual ECO and ECO COM B USB ...

Page 2: ...2 Version Version ECO_M_ENG_220303_E001 Manual Version ECO_M_ENG_220303_E001 ...

Page 3: ...Plug tap 9 4 2 Electrical Installation 9 4 3 Ex Installation 10 5 OPERATION 11 5 1 Normal Operation 11 5 2 Possible output configurations 11 5 2 1 Digital configurations 11 5 2 2 Analog configurations 12 5 2 3 0 10V active Frequency Pulse PP NPN PNP ECO XX FW XX X 14 5 3 Parameterization 15 5 3 1 Installation of KEM EcoControl 15 5 3 2 Connect ECO with PC laptop 15 5 3 3 Adjustment notes 17 6 SERV...

Page 4: ...ant information for the correct usage of the equipment If the notes are not observed a malfunction of the equipment is possible WARNING Warnings provide very important information for the correct usage of the equipment Not observing the warnings may lead to danger for the equipment and to danger for health and life of the user ...

Page 5: ... will only apply when all connectors are caped properly with the corresponding counterpart with the same or better IP rating Cable glands must be populated with cables with the specified diameter and closed properly During operation all openings of the housing must be closed unless otherwise noted in this manual All connections to the load and to the supply must be made with shielded cables unless...

Page 6: ...6 General Information Version ECO_M_ENG_220303_E001 Order designations and accessories 2 1 3 Ordering Code ...

Page 7: ...ation KEM EcoControl P Parameterization software for WINDOWS The minimum installation requirements Windows 10 3 Getting started 3 1 Unpacking Verify that you have received the following items When you ordered ECO ECO User s manual Conformation declaration EU When you ordered ECO COM B USB ECO COM B USB USB 2 0 cable A B 1 5m CD with KEM EcoControl Software an USB drivers 3 2 Ordering Elements 3 2 ...

Page 8: ...M B USB Abb 2 Bedienelemente von ECO COM B USB 1 Cable screw connection M12 socket for connection to ECO 2 Control LED 3 3 PIN Assignments 3 3 1 ECO 1 Vcc Loop 24 V 2 Digital Output 2 NAMUR 3 GND Loop 4 Digital Output 2 NAMUR 5 Active Analog Output 1 4 5 2 3 1 2 ...

Page 9: ...4x1 5 mounting thread of the measuring cell until it stops WARNUNG Too much force will damage the sensor tip Turn the ECO back by 15 Fix the ECO with the lock nut on the sensor tip 4 2 Electrical Installation HINWEIS For connecting shielded cables must be used The ECO housing is connected to the cable shield WARNING Improper grounding and shielding may lead to bad EMC behavior or danger to your he...

Page 10: ...trinsically save when operated with zener barriers Follow the installation instructions from the chapter 4 1 Connect the ECO to isolation amplifiers via a shielded cable WARNING When used in hazardous areas the ECO must not be connected to any circuitry except suitable zener barriers ...

Page 11: ... the frequency range must still be set EcoControl 5 2 1 Digital configurations The frequency pulse and NAMUR configurations are called digital configurations With dual channel versions ECO X2 you have the possibility to output the measured sensor signals directly scaled up to approx 5 kHz or the direction information For single channel versions ECO X1 only the flow information is available 5 2 1 1...

Page 12: ...erface 5 2 2 Analog configurations In addition to the frequency pulse information analog configurations offer the possibility of outputting a further analog output variable The flow rate or the medium temperature is available as the reference variable for this analog information The analog outputs also have the option of signaling an error 5 2 2 1 4 20 mA Passive Frequency Pulse NPN ECO XX AN XX X...

Page 13: ...CO_M_ENG_220303_E001 5 2 2 2 0 20 mA Active Frequency Pulse PP NPN PNP ECO XX FV XX X This configuration offers an active current loop in addition to the frequency pulse functionality Fig 4 EcoControl configuration interface ...

Page 14: ...ECO_M_ENG_220303_E001 5 2 3 0 10V Active Frequency Pulse PP NPN PNP ECO XX FW XX X Here in addition to the frequency pulse functionality an active voltage output 0 10 V is available Fig 5 EcoControl configuration interface ...

Page 15: ...tallation of KEM EcoControl You can find the EcoControl software in the download area of the KEM website There is an installer that installs all the necessary components on your PC laptop 5 3 2 Connect ECO with PC laptop Plug the ECO COM B USB into a free USB USB A port Start the program In the upper part of the screen there is an area Connection Fig 6 Connection on the EcoControl configuration in...

Page 16: ...rmation is also available here only ECO without sensor marked by All input fields are outlined in orange and can be changed Sensor Serial Number and Sensor Model Code should be taken from the calibration protocol or the type plate of the sensor Fig 8 Selection of the sensor or entry of the K factor When you select a sensor the standard measuring range and via the K factor also the measured frequen...

Page 17: ...intervals For the best performance we recommend a calibration of current output in the interval of 5 years The calibration can be carried out by ECO COM B USB and the software KEM EcoControl directly from the customer or in our production 6 2 Trouble Shooting In case the ECO does not work properly first check the following items No output signal All cables properly connected as described in chapte...

Page 18: ...n case of malfunction please contact your nearest dealer or directly KEM For the addresses see the last page of this document 7 Important Informationen 7 1 Warranty For warranty refer to the general terms and conditions of KEM Küppers Elektromechanik GmbH which can be found on the corresponding website www kem kueppers com ...

Page 19: ... 5 Ambient Temperature 40 C 60 C 40 F 140 F Medium Temperature Flush Mount 1 or 2 Channel 40 C 80 C 40 F 176 F Screw in M14x1 5 1 Channel 40 C 120 C 40 F 248 F 40 C 150 C 40 F 302 F Housing Material Aluminium die casting alloy 231 or Stailness Steel Sensor Probe Material 1 4404 AISI 316L all Variants Protection Class Aluminium IP65 Stailness Steel IP68 Weight approx 200 g Electrical Connection Sho...

Page 20: ... 28 V NAMUR 4 20 mA passive Frequency Pulse NPN 𝑅𝑅𝐿𝐿𝐿𝐿𝐿𝐿𝐿𝐿 𝑉𝑉𝑐𝑐𝑐𝑐 15 𝑉𝑉 0 021𝐴𝐴 min max RL 300 Ω IL 21 mA Vcc 21 6 V 28 V 4 20 mA active Frequency Pulse PP NPN PNP 𝑅𝑅𝐿𝐿𝐿𝐿𝐿𝐿𝐿𝐿 𝑉𝑉𝑐𝑐𝑐𝑐 15 𝑉𝑉 0 021𝐴𝐴 min max RL 600 Ω IL 21 mA UL 25 V Vcc 16 8 V 28 V ECO Pin 1 Vcc Pin 2 4 Pin 3 GND RL ECO Pin 1 Vcc Pin 2 4 Pin 3 GND ECO Pin 1 Vcc Pin 2 4 Pin 3 GND ECO Pin 1 Loop Pin 2 4 Pin 3 GND Loop RL ECO Pin 1 Vcc ...

Page 21: ...n Product Certification Code T100 Zulassungen ATEX IECEx Zone1 CAUK Ex II 2G Ex ia IIC T4T3 Gb cCSAus Class1 Div1 Groups A B C D T4T3 Class1 Zone1 Groups A B C D T4T3 Temperature T4 135 C Tamb 40 C to 60 C T3 200 C Tamb 40 C to 85 C Design Values Supply and Puls Frequency Outputs Ui DC 28 V I i 93 mA Pi 650 mW ECO Pin 1 24V Pin 2 4 PP PNP NPN Pin 3 GND Pin 5 U VO ...

Page 22: ...22 Important Informationen Version ECO_M_ENG_220303_E001 7 3 Dimensional Drawings Fig 3 Dimensional Drawings ECO ...

Page 23: ...ic waste The unit described herein fully complies with the RoHS directive 7 5 List of Figures Fig 1 EcoControl configuration interface 11 Fig 2 EcoControl configuration interface 12 Fig 3 EcoControl configuration interface 12 Fig 4 EcoControl configuration interface 13 Fig 5 EcoControl configuration interface 14 Fig 6 Connection on the EcoControl configuration interface 15 Fig 7 directly after con...

Page 24: ...941 9423 23 production kem kueppers com KEM Vertrieb Liebigstraße 5 85757 Karlsfeld Deutschland T 49 8131 59391 100 F 49 8131 92604 sales kem kueppers com KEM Service Reparaturen Wettzeller Straße 22 93444 Bad Kötzting Deutschland T 49 9941 9423 37 F 49 9941 9423 24 service kem kueppers com Weitere Distributoren Partner finden sie unter www kem kueppers com Original KEM Dokument ECO_M_ENG_220303_E...