![Kelvinator R-404A Installation Manual Download Page 20](http://html1.mh-extra.com/html/kelvinator/r-404a/r-404a_installation-manual_4092203020.webp)
18
PRINCIPLES OF OPERATION
SYSTEM INFORMATION - E4HR & E4HC (220V / 50 Hz)
ELECTRICAL
E4HR2 & E4HC2 (220V / 60 Hz)
REFRIGERATION -
Refrig. Charge: R-404A / 11.5 oz. / 326.02 grams / No. 4 Stat Position
Compressor
Manufacturer: Americold
Model: HP-110-12-3084
V.: 220
R.L.A.: 2.0
L.R.A.: 12.6 Phase: 1/50Hz.
Overload Protector
T.I.: Americold #1456-3444
Start Relay
T.I.: Americold #1456-3374
Start Capacitor
V.A.C.: 250
M.F.: 108-130
Run Capacitor
V.A.C.: 370
M.F.: 7.5
Condenser
Manufacturer: Heatcraft
Condenser
Manufacturer: G.E.
Fan Motor
Model: 5KSM51ECG3905
Condenser
Diameter: 8" # of Blades: 3
Fan Blade
Width of Blades: 1 7/8"
Power Cord
A.W.G.: 14
A.: 15 @ 125V
Light Ballast
Robertson #02025 (50Hz)
Robertson #02026 (60Hz)
Fluorescent
Manufacturer: G.E.
Lamp
F20T12/CW
Evaporator
Cold Wall
Capillary Tube
7' of .031
Thermostat
Manufacturer: Ranco
F.L.A.: 25
V.: 120/240 L.R.A.: 100
Warm Cut-in 11° Warm
Cut-out
—
Mid Cut-in
-12°
Mid Cut-out
-24°
Cold Cut-in
—
Cold Cut-out
-34°
AMBIENT TEMPERATURE
70°F / 21.1°C
80°F / 27°C
90°F / 32.5°C
CONTROL SETTINGS
#4 C.S.
#4 C.S.
#4 C.S.
Cavity Temperature C.L.
0°F / -17°C
2°F / -16°C
3°F / -16°C
Suction Pressure - C.O.
PSIG/Kpa
12 / 82
13 / 89
14 / 96
Discharge Pressure - C.O. PSIG/Kpa
206 / 1420
214 / 1475
239 / 1647
Compressor Amps
2.0
2.0
2.0
Total Cabinet Amps
2.3
2.3
2.3
Dipping Cabinet 1298.02 2/3/03 1:14 PM Page 20
Summary of Contents for R-404A
Page 3: ...Introduction...
Page 13: ...SECTION II Principles of Operation...
Page 14: ......
Page 28: ......
Page 29: ...SECTION III Maintenance Repair...
Page 55: ...PARTS LISTING With Illustration Identification...
Page 56: ...CABINET PARTS EXPLODED VIEW 54 CABINET PARTS EXPLODED VIEW 2 1 3 4 7 9 8 6 10 11 5...
Page 60: ...CONDENSING UNIT EXPLODED VIEW 58 CONDENSING UNIT EXPLODED VIEW...
Page 62: ...ELECTRICAL PARTS EXPLODED VIEW 60 ELECTRICAL PARTS EXPLODED VIEW...
Page 64: ...1 6 7 2 4 3 5 LID EXPLODED VIEW 62 LID EXPLODED VIEW...
Page 66: ......
Page 67: ...ACCESSORIES...
Page 68: ......
Page 73: ...ADJUSTABLE LEG KIT 52 1831 01 ACCESSORIES 71...
Page 74: ...CASTER KIT 52 1830 01 72 ACCESSORIES...
Page 76: ...CAN CLAMP INSTALLATION 74 ACCESSORIES...
Page 79: ......
Page 80: ...by National Refrigeration Products 563 Corbin Road Honea Path South Carolina 800 486 8369...