10  troubleshooting  

Kelvinator Air Conditioning

Problem

Solution

Air 
conditioner
cooling, but 
room is too 
warm- ice
forming 
on cooling 
coil behind 

 

Outdoor temperature below 18°C(64°F). 
To defrost the coil, set selector to FAN position. 
Then, set thermostat to warmer position.

Air filter may be dirty. Clean filter. Refer to 
Care and Cleaning section. To defrost, set 
selector to FAN.

Thermostat set too cold for night-time cooling. 
To defrost the coil, set selector to a FAN position. 
Then, set thermostat to a warmer position.

Air 
conditioner
cooling, but 
room is too 
warm- NO
ice forming 
on cooling 
coil behind

Dirty air filter- air restricted. Clean air filter.  
Refer to Care and Cleaning section.

Thermostat set too warm. Turn thermostat 
clockwise to a colder setting.

Air directional louvres positioned improperly. 
Position louvres for better air distribution.

Front of units is blocked by drapes, blinds, 
furniture, etc. - restricts air distribution. Clear 
blockage in front of unit.

Doors, windows, registers, etc. Open-cold air 
escapes. Close doors, windows, registers.

Unit recently turned on in hot room. Allow 
additional time to remove Stored heat from
walls, ceiling, floor and furniture.

Air 
conditioner 
turns on and 
off rapidly

Dirty air filter- air restricted. Clean air filter.

Outside temperature extremely hot. Set to 
high cool to bring air past cooling coils 
more frequently

Noise when 
unit is cooling

Air movement sound. This is normal . If too loud, 
turn selector to lower FAN setting.

Sound of fan hitting water-moisture removal 
system. This is normal when humidity is high. 
Close doors, windows and registers.

Window vibration - poor installation. Refer to 
installation instructions or check with installer.

Water 
dripping
INSIDE when
unit is cooling.

Improper installation. Tilt air conditioner slightly 
to the outside to allow water drainage. Refer to 
installation instructions - check with installer.

Water 
dripping
OUTSIDE 
when unit is 
cooling.

Unit removing large quantity of moisture from 
humid room. This is normal during excessively 
humid days.

Before calling for service, review this list. It may save you 
time and money. This list includes common occurrences that 
are not the result of defective workman-ship or materials in 
this appliance.

Problem

Solution

Air 
conditioner
does not start

Wall plug disconnected. Push plug firmly into 
wall outlet.

House fuse blown or circuit breaker tripped. 
Replace fuse with time delay type or reset 
circuit breaker.

Selector Control in OFF position. Turn selector 
to the desired FAN or COOL setting.

Unit turned off by moving thermostat to a higher 
number and then immediately turning back to a 
colder number. Wait approximately 3 minutes. 
Listen for compressor to start.

Unit turned off and then on too quickly. Turn unit 
off and wait 3 minutes before restarting.

Thermostat set too low. Adjust thermostat to 
cooler setting for cooling.

Air from unit 
does not feel 
cold enough

Turn selector to a higher COOL position.

Thermostat set too warm. Set thermostat to 
colder temperature.

Room temperature below 18°C(64°F). Cooling 
may not occur until room temperature
rises above 18°C(64°F).

Troubleshooting tips

Summary of Contents for KWH16CMF

Page 1: ...Window Wall Manual Room Air Conditioner User Manual KWH16CMF Refrigerant R32 ...

Page 2: ...echanic with knowledge of appropriate gas reclamation methods Do not use means to accelerate defrosting or to clean other than those recommended by the manufacturer The appliance shall not be stored in a room with continuously operating ignition sources Do not pierce or burn caution The air conditioner is not intended for use by young children or infirm persons without supervision Young children s...

Page 3: ...stibles such as gasoline benzene thinner etc It may cause an explosion or fire Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire and burns Do not disassemble or modify unit It may cause failure and electric shock Safety precautions Kelvinator Air Conditioning important safety instructions 3 caution Contact an authorised ser...

Page 4: ...m well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation and close the window in storm or ...

Page 5: ...the power outlet used for this product has suitable current rating should be provided with reliable earth wire power cord A E N Fig 1 Fig 2 wall outlet air break switch E earthwire yellow green N neutral wire blue A active wire brown The operation panel of your unit will look like the following NOTE The outline of the operation panel is based on typical model the function is the same with your air...

Page 6: ...or the units with AIR SWING feature automatic When the AIR SWING switch is turned to ON position the vertical louvres automatically oscillate right and left sweeping the cold air around to obtain comfortable cooling The vertical louvres may be stopped at any position when the AIR SWING switch is turned OFF AUTO SWING OFF ON On some models To adjust horizontal ai ow direction move the lever gently ...

Page 7: ... The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air condit...

Page 8: ...use it will prevent heat radiation of the condensor Restriction of outside air will greatly reduce the cooling and heating e ciency of the air conditioner 4 5 Install the unit with its bottom portion 75 150cm above th oor level t n e d n e p e d n i n a o t d e t c e n n o c e b t s u m d r o c r e w o p e h T 6 circuit The yellow green wire must be grounded 7 Based on calculations in compliance w...

Page 9: ...d water 1 Take out the drain pan and screws provided within your air conditioner accessories bag 2 Install the drain pan at the bottom of the unit and secure it with the screws provided 3 Connect a suitable sized drain hose not supplied to the drain outlet located on the underside of the drain pan Drain plug Cooling only models The drain plug is fitted from the factory to capture condensed water t...

Page 10: ...FAN setting Sound of fan hitting water moisture removal system This is normal when humidity is high Close doors windows and registers Window vibration poor installation Refer to installation instructions or check with installer Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions che...

Page 11: ...Kelvinator Air Conditioning warranty 11 ...

Page 12: ... information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 13 13 49 email customercare electrolux com au web kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au 66129933408 ...

Reviews: