  electrical work/checking the drainage and forming piping  17

16  electrical work  

Kelvinator Air Conditioning

Checking the drainage

A:  To remove the front panel from the indoor unit.

•   Pull the lower left and right sides of the grille towards 

you and lift it up.

Downward

s lope

Water

leakage

Water

leakage

Water

leakage

Air

Do not 

raise

Accumulated

drain water

Tip of drain hose

dipped in water

Ditch

Less  than

50mm gap

B:  To check the drainage

•  Pour a glass of water on the evaporator.
•   Ensure the water flows through the drain hose of the 

indoor unit without any leakage and goes out the 
drain exit.

Downward

s lope

Water

leakage

Water

leakage

Water

leakage

Air

Do not 

raise

Accumulated

drain water

Tip of drain hose

dipped in water

Ditch

Less  than

50mm gap

C:  Drain piping

•   The drain hose should point downward for easy 

drain flow.

•   Do not make drain piping similar to diagrams shown 

below on the right.

Downward

s lope

Water

leakage

Water

leakage

Water

leakage

Air

Do not 

raise

Accumulated

drain water

Tip of drain hose

dipped in water

Ditch

Less  than

50mm gap

Checking the drainage and forming 

the piping

8   The following may be caused by voltage drop.

 

 Vibration of a conductor, which will damage the contact 
point, fuse blowing, disturbance of the normal function 
of the overload.

9   The means for disconnection of a power supply shall 

be incorporated in the fixed wiring and have an air 
gap contact separation of at least 3mm in each active 
(phase) conductor.

If a power plug is not to be used, provide a Circuit Breaker/
Fuse between power source and the unit as shown in the 
diagram below.

40mm

10m

m

L

S

  N

To indoor unit

L(1 )

L( 1)

L

S

  N

9000Btu/h model(2.6kw)

18000Btu/h model(5.3kw)

24000Btu/h model(7.0kw)
28000Btu/h model(8.0kw)

12000Btu/h model(3.5kw)

21000Btu/h model(6.2kw)

Wire connector of outdoor unit

Wire-holding

board

To indoor unit

To power supply

To indoor unit

To power supply

caution

After confirming the above conditions, prepare the wiring 
as follows:

1   never fail to have an individual power circuit specifically 

for the air conditioner. As for the method of wiring, 
be guided by the circuit diagram posted on the inside 
of the control cover.

2   The screws which fasten the wiring in the casing of 

electrical fittings may come loose from vibrations 
to which the unit is subjected during the course of 
transportation. Check them and make sure that they 
are all tightly fastened. If they are loose, it could cause 
burn-out of the wires.

3  Specification of power source. 
4   Confirm that electrical capacity of the installation 

is sufficient.

5   Ensure that the starting voltage is maintained at more 

than 90 percent of the rated voltage marked on the 
name plate.

6   Confirm that the cable thickness is as specified in 

the power source specification. Particularly note the 
relation between cable length and thickness (Refer 
to page 14).

7   Always install a Residual Current Device (RCD) in wet 

or moist area.

Length of the power supply cord should be at least 1.8m. 
Measure from the power supply cord entry of the cabinet 
to the middle of the live pin of the plug.

Model Capacity

Power 

Source

Circuit 

Breaker 

/Fuse 

Rating

Wire Size

2.6kw

50Hz 

220-240V

10A

≥1.0mm

2

3.5kw

10A

≥1.0mm

2

5.3kw

16A

≥1.5mm

2

6.2kw

16A

≥1.5mm

2

7.0kw

16A

≥1.5mm

2

8.0kw

20A

≥2.5mm

2

Note: To be used as a guide only.

caution

 

Ensure that all electrical work complies with relevant 
Standards and Supply Authority Service Rules.
An individual branch Circuit Breaker/Fuse must be used with 
this Air Conditioner. See the table for electrical requirements.

Note:

•    Power Source and Power Cord specifications must 

comply with requirements above.

•   Circuit Breaker or Fuse specified in this manual must be 

installed in the power supply circuit.

•   For your safety and protection, this unit is earthed 

through the power cord plug when plugged into a 
matching wall receptacle.

•   Do not connect two power cords together to supply 

power to the air conditioner.

•  Do not extend the power cable conductors by cutting.

Connect the cable to the outdoor unit

A:   Remove the control cover from the unit by loosening 

the screw. 
Connect the wires to the terminals on the control 
board individually.

B:   Secure the cable onto the control board with the 

cord clamp.

C:   Refix the control cover to the original position with 

the screw.

D:   Use a recognised circuit breaker (See page 17) between 

the power source and the unit. An isolation device to 
adequately disconnect all supply lines must be fitted.

Summary of Contents for KSV26HRB

Page 1: ...Inverter Split type Room Air Conditioner Installation Manual KSV26HRB KSV35HRB KSV53HRB KSV62HRB KSV70HRB KSV80HRB Refrigerant R410A ...

Page 2: ...g the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this Important safety instructions 2 Contents Kelvinator Air Conditioning Congratulations and thank you for ...

Page 3: ...fied torque wrenches 1 8kgf m 4 2kgf m 5 5kgf m 6 6kgf m different depending on model No Spanner half union Hexagonal wrench 4mm Gas leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape Items required for installing the unit Number Name of Accessories Qty 1 Installation Plate 1 2 Clip Anchor 8 3 Self tapping Screw A 8 4 Seal See page 8 for details...

Page 4: ... unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the space on the left and right of the unit is more than 12cm Use a stud finder to locate studs to prevent unnecessary damage to the wall The indoor unit should be installed on the wall at a height of 2 0m or more from the floor The indoor unit should be installed allowing a minimum...

Page 5: ... pipe hole 65 Left rear side refrigerant pipe hole 65 12cm or more to wall 12cm or more to wall 850 45 90 45 45 272 80 489 6 2kw model 12cm or more to the wall to the wall 12cm or more 50 15cm or more to the ceiling Indoor Unit Outline 380 Hooked Part 380 998 322 119 130 65 65 130 50 Above 12cm to the wall Above 12cm to the wall Above 15cm to the ceiling 325 55 95 95 55 1250 815 257 178 55 58 Pipe...

Page 6: ...ing of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount Model A mm B mm 3 5kw 530 290 5 3kw 560 335 6 2kw 590 333 A B Air inlet Air outlet Air inlet Drain joint installation If a drain elbow is used the unit should be placed on a stand which is taller than 3cm If the unit is used in an area where temperature falls below 0O C for...

Page 7: ...ing section C Tape the tubing drain hose and the connecting cable Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Note If the drain hose is routed inside the room insulate the hose with insulation material so that dripping from sweating condensation will not damage furniture or floors Foamed polyethy...

Page 8: ...n screw Tubing retainer I Reroute the piping and the drain hose across the back of the chassis for rear left side external passage J Locating the indoor unit Remove the spacer Hook the indoor unit onto the upper portion of the installation plate Engage the hooks of the installation plate into the openings at the rear top of the indoor unit Ensure that the hooks are properly seated on the installat...

Page 9: ...rcuit diagram posted on the inside of the control cover 2 The screws which fasten the wiring in the casing of electrical fittings may come loose from vibrations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could cause burn out of the wires 3 Specification of power source 4 Confirm that electrical...

Page 10: ...an the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter 76cmHg Handle L o Handle Hi Charge hose Charge hose Vacuum pump Pressure gauge Low pressure valve Air purging Air purging Air and moisture in the refrigerant system have undesirable effects as ...

Page 11: ...AUTO or COOL mode see User Manual for details The test operation should last about 30 minutes Manual control button AUTO COOL Rated Capacity Test Cooling mode Under Cooling Mode set the air conditioner at High Fan Speed and set the temperature to 17O C then press the TURBO button 6 times within 10 seconds be sure the indoor unit buzzes 6 times The system will enter Rated Capacity Test mode The buz...

Page 12: ...rchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and t...

Page 13: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: