Indoor electric wiring
Note: for correct operation of the air conditioner and standby
power modes the mains power should be supplied to the
indoor unit.
1. Open the front panel and remove the wiring cover by
loosening the screw.
wiring cover
N(1) 2 4 5
N(1) 2
3
N(1) 2
2. Route the power connection cable from back of the indoor
unit and pull it toward the front through the wiring hole for
connection.
3. Connect and screw the wires onto the terminal block as
identified by their colours.
KSV26CRE, KSV35CRE models
blue
black
brown
to outdoor unit
cable clamp
earthing wire
(green & yellow)
KSV26HRE, KSV35HRE models
blue
black
brown
earthing wire
(green and yellow)
4. Wrap wires that are not connected with insulating tape so that
they do not touch any electrical or metal parts.
5. Secure the wires firmly with the cable clamp.
6. Put the wiring cover back and screw it.
7. Reinstall the front panel.
warning
All wires between indoor and outdoor units must be connected by
a qualified electric contractor.
If the length of the power cord is not enough, please contact your
installer for new a power cord. Lengthening the power cord by
yourself is dangerous and illegal.
Note: Powered accessories cannot be connected to these wiring
points
After tightening the screws, pull the wire slightly to confirm whether
it’s firm or not.
Do not connect two power cables together to supply power to the
air conditioner.
Do not extend the power cable conductor by cutting or splicing.
Installation
20 I nstallation instructions
Kelvinator Air Conditioning