14
Special functions
SLEEP operation
SLEEP operation
Cooling
Heating
SLEEP operation
Continuous run
Continuous run
1 hour
1 hour
1°C
1°C
1°C
1°C
1 hour
1 hour
Set temp.
Set temp.
When selected, the set temperature will increase (cooling) or
decrease (heating) by 1°C per hour for the first 2 hours. Until new
settings are entered or the air conditioner is shut down.
Sleep function saves energy and improves night time by optimising
sleeping temperature.
Refrigerant leakage detection
When refrigerant leakage is detected, the indoor unit will display
EC code.
Louvre angle memory function
Within the scope of safety angle, the horizontal louver angle is
memorised and will return to the position last selected by user. If it
exceeds, it will memorize the boundary of safety angle. This will not
happen when Turbo or manual control buttons are pressed or after
a power interruption. So we strongly suggest that the open angle
of the horizontal louver should not be set too small, in case the
condensed water forms and drips from the horizontal louver.
SELF CLEAN function
•
Airborne bacteria use the moisture on the indoor heat
exchanger to grow. Regular drying of the exchanger prevents
this growth. By simply pressing the SELF CLEAN button, the
system will automatically manage the process. This cleaning
action may be done as frequently as desired.
•
For cooling models, only the indoor fan is active in low speed
for 30 minutes and the unit turns off automatically.
•
For cooling & heating models, the unit will operate as in the
following sequence : FAN mode at Low fan speed--Heating
operation with LOW fan speed ---FAN operation--Stop
Operation---Turn off.
NOTE:
•
Activating self clean function does not replace the need to
clean the filters. The filters must be cleaned at least every
3 months, or as required to maintain good cleanliness and
performance of this air conditioner.
•
This function is only activated in COOLING or DRY mode.
•
Before activation the air conditioner, it is recommended
to run the air conditioner under cooling operation for about
30 minutes.
•
Pressing the SELF CLEAN or ON/OFF button again during the
cleaning cycle will cancel the operation and turn the unit off.
Auto-restart function
In event of power interruption such as a blackout, the air
conditioner stops once. But it restarts automatically and performs
previous operation when the power supply is resumed.
Mute operation
Press the LED button on the remote controller can turn off the
indoor screen display, and also turn off the Air conditioner buzzer,
which create a comfortable and quiet environment.